{"id":62978,"date":"2024-10-17T12:05:52","date_gmt":"2024-10-17T12:05:52","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d4566-2005\/"},"modified":"2024-10-24T18:07:40","modified_gmt":"2024-10-24T18:07:40","slug":"astm-d4566-2005","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d4566-2005\/","title":{"rendered":"ASTM-D4566 2005"},"content":{"rendered":"<\/p>\n

1.1 These test methods cover procedures for electrical testing of thermoplastic insulations and jackets used on telecommunications wire and cable and for the testing of electrical characteristics of completed products. To determine the procedure to be used on the particular insulation or jacket compound, or on the end product, reference should be made to the specification for the product.<\/p>\n

1.2 The test methods appear in the following sections of this standard:<\/p>\n

1.3 The values stated in inch-pound units are to be regarded as the standard. SI units are for information only.<\/p>\n

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Sections and .<\/p>\n

1.4 In-process electrical tests are used primarily as process control tools in an attempt to minimize the number and magnitude of problems detected at final test of completed cable.<\/p>\n

1.5 Electrical tests of completed wire and cable may include verification of some or all of the properties in accordance with Sections through .<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents <\/td>\n<\/tr>\n
2<\/td>\nTerminology
Scope
Significance and Use
Spark Test <\/td>\n<\/tr>\n
3<\/td>\nInsulation Defect or Fault Rate\u2014In-Process
DC Proof Test\u2014In-Process
Scope
Significance and Use
Conductor Continuity <\/td>\n<\/tr>\n
4<\/td>\nContinuity of Other Metallic Cable Elements
Conductor Resistance (CR)
Resistance of Other Metallic Cable Elements
Conductor Resistance Unbalance (CRU of Pairs) <\/td>\n<\/tr>\n
5<\/td>\nMutual Conductance
Coaxial Capacitance (Capacitance to Water)
Mutual Capacitance (CM) <\/td>\n<\/tr>\n
6<\/td>\nCapacitance Deviation
FIG. 1 <\/td>\n<\/tr>\n
7<\/td>\nCapacitance Difference (Filled Core only)
Capacitance Unbalance\u2014Pair-to-Pair (CUPP)
FIG. 2 <\/td>\n<\/tr>\n
8<\/td>\nCapacitance Unbalance\u2014Pair-to-Ground (CUPG)
Capacitance Unbalance\u2014Pair-to-Support Wire
Attenuation
FIG. 3 <\/td>\n<\/tr>\n
9<\/td>\nFIG. 4
FIG. 5 <\/td>\n<\/tr>\n
10<\/td>\nCrosstalk Loss\u2014Near End <\/td>\n<\/tr>\n
11<\/td>\nAttenuation to Crosstalk Ratio, Near-End (ACR-N)
Crosstalk Loss\u2014Far End <\/td>\n<\/tr>\n
12<\/td>\nAttenuation to Crosstalk Ratio, Far-End (ACR-F) <\/td>\n<\/tr>\n
13<\/td>\nEffects of Elevated Temperature on Attenuation <\/td>\n<\/tr>\n
14<\/td>\nEffects of Humidity on Attenuation
Effects of Aging on Attenuation <\/td>\n<\/tr>\n
15<\/td>\nInsulation Resistance (IR)
Fault Rate (Air Core Only)
Shorts Test (Between Wires of a Pair)
Crosses Test (Between Wires of Different Pairs) <\/td>\n<\/tr>\n
16<\/td>\nJacket Voltage Breakdown Rating Test
DC Proof Test\u2014Wire-to-Wire
DC Proof Test\u2014Core-to-Shield
DC Proof Test\u2014Core-to-Support Wire <\/td>\n<\/tr>\n
17<\/td>\nDC Proof Test\u2014Core-to-Internal Shield (Screen)
DC Proof Test\u2014Internal Shield (Screen)-to-Shield
DC Proof Test\u2014Other Required Isolations
Voltage Surge Test
Phase Constant <\/td>\n<\/tr>\n
18<\/td>\nPhase Delay
Phase Velocity
FIG. 6 <\/td>\n<\/tr>\n
19<\/td>\nCharacteristic Impedance\u2014Method 1
Characteristic Impedance\u2014Method 2
Single Ended Measurements <\/td>\n<\/tr>\n
21<\/td>\nCharacteristic Impedance\u2014Method 3 <\/td>\n<\/tr>\n
23<\/td>\nStructural Return Loss (SRL) and Return Loss (RL)
Unbalance Attenuation (Mode Conversion Losses) <\/td>\n<\/tr>\n
24<\/td>\nFIG. 7 <\/td>\n<\/tr>\n
25<\/td>\nFIG. 8
FIG. 9 <\/td>\n<\/tr>\n
26<\/td>\nReport
Keywords
A1. CALIBRATION PROCEDURE FOR CHARACTERISTIC IMPEDANCE AND SRL DATA ACQUISITION
A1.1 S-Parameter Calibration of Network Analyzer when Internal Calibration is not available
FIG. 10 <\/td>\n<\/tr>\n
27<\/td>\nA2. UNBALANCE ATTENUATION
A2.1 General
A2.2 Unbalance Attenuation Near End and Far End
TABLE A2.1
TABLE A2.2 <\/td>\n<\/tr>\n
28<\/td>\nTABLE A2.3
FIG. A2.1
FIG. A2.2 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

D4566-05e1 Standard Test Methods for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2005<\/td>\n29<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":62979,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[476,2637],"product_tag":[],"class_list":{"0":"post-62978","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-035-01","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/62978","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/62979"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=62978"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=62978"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=62978"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}