{"id":439479,"date":"2024-10-20T08:09:18","date_gmt":"2024-10-20T08:09:18","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iso-80601-2-722023-tc\/"},"modified":"2024-10-26T15:16:35","modified_gmt":"2024-10-26T15:16:35","slug":"bs-en-iso-80601-2-722023-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iso-80601-2-722023-tc\/","title":{"rendered":"BS EN ISO 80601-2-72:2023 – TC"},"content":{"rendered":"
This document applies to the basic safety and essential performance of a ventilator in combination with its accessories, hereafter referred to as ME equipment: \u2014 intended for use in the home healthcare environment; \u2014 intended for use by a lay operator; and \u2014 intended for those patients who need differing levels of support from artificial ventilation including for ventilator-dependent patients. This document is also applicable to those accessories intended by their manufacturer to be connected to a ventilator breathing system or to a ventilator where the characteristics of those accessories can affect the basic safety or essential performance of the ventilator.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 30477240 <\/td>\n<\/tr>\n | ||||||
235<\/td>\n | A-30441458 <\/td>\n<\/tr>\n | ||||||
236<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
238<\/td>\n | European foreword Endorsement notice <\/td>\n<\/tr>\n | ||||||
243<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
245<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
247<\/td>\n | 201.1 Scope, object, and related standards 201.1.1 Scope <\/td>\n<\/tr>\n | ||||||
248<\/td>\n | 201.1.2 Object 201.1.3 Collateral standards <\/td>\n<\/tr>\n | ||||||
249<\/td>\n | 201.1.4 Particular standards 201.2 Normative references <\/td>\n<\/tr>\n | ||||||
251<\/td>\n | 201.3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
267<\/td>\n | 201.4 General requirements <\/td>\n<\/tr>\n | ||||||
268<\/td>\n | Table 201.101 \u2014 Distributed essential performance requirements <\/td>\n<\/tr>\n | ||||||
269<\/td>\n | 201. 4.4 Additional requirements for expected service life <\/td>\n<\/tr>\n | ||||||
271<\/td>\n | 201.5 General requirements for testing of ME equipment <\/td>\n<\/tr>\n | ||||||
272<\/td>\n | 201.6 Classification of ME equipment and ME systems 201.7 ME equipment identification, marking, and documents <\/td>\n<\/tr>\n | ||||||
273<\/td>\n | 201. 7.2.18 Additional requirements for external gas source <\/td>\n<\/tr>\n | ||||||
281<\/td>\n | 201.8 Protection against electrical hazards from ME equipment 201.9 Protection against mechanical hazards of ME equipment and ME systems <\/td>\n<\/tr>\n | ||||||
283<\/td>\n | Table 201.102 \u2014 Test conditions for acoustic tests 201.10 Protection against unwanted and excessive radiation hazards <\/td>\n<\/tr>\n | ||||||
284<\/td>\n | 201.11 Protection against excessive temperatures and other hazards Table 201.103 \u2014 Examples of permissible combinations of temperature and relative humidity <\/td>\n<\/tr>\n | ||||||
286<\/td>\n | 201.12 Accuracy of controls and instruments and protection against hazardous outputs <\/td>\n<\/tr>\n | ||||||
288<\/td>\n | Figure 201.101 \u2014 Typical test setup for volume-control and pressure-control inflation-type accuracy <\/td>\n<\/tr>\n | ||||||
289<\/td>\n | Table 201.104 \u2014 Volume-control inflation-type settings <\/td>\n<\/tr>\n | ||||||
291<\/td>\n | Table 201.105 \u2014 Pressure-control inflation-type settings <\/td>\n<\/tr>\n | ||||||
305<\/td>\n | 201.13 Hazardous situations and fault conditions <\/td>\n<\/tr>\n | ||||||
307<\/td>\n | 201.14 Programmable electrical medical systems (PEMS) 201.15 Construction of ME equipment <\/td>\n<\/tr>\n | ||||||
308<\/td>\n | 201.16 ME systems <\/td>\n<\/tr>\n | ||||||
309<\/td>\n | 201.17 Electromagnetic compatibility of ME equipment and ME systems 201.101 Gas connections <\/td>\n<\/tr>\n | ||||||
312<\/td>\n | 201. 101.2.2.8 Temperature sensor port 201.102 Requirements for the VBS and accessories <\/td>\n<\/tr>\n | ||||||
313<\/td>\n | 201.103 Spontaneous breathing during loss of power supply <\/td>\n<\/tr>\n | ||||||
314<\/td>\n | 201.104 Indication of duration of operation 201.105 Functional connection <\/td>\n<\/tr>\n | ||||||
315<\/td>\n | 201.106 Display loops 201.107 Ventilator security <\/td>\n<\/tr>\n | ||||||
316<\/td>\n | 201.108 Oxygen inlet port 202 Electromagnetic disturbances \u2014 Requirements and tests <\/td>\n<\/tr>\n | ||||||
317<\/td>\n | 206 Usability <\/td>\n<\/tr>\n | ||||||
319<\/td>\n | 208 General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems <\/td>\n<\/tr>\n | ||||||
321<\/td>\n | 211 Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment <\/td>\n<\/tr>\n | ||||||
324<\/td>\n | Annex C (informative) Guide to marking and labelling requirements for ME equipment and ME systems Table 201.C.101 \u2014 Marking on the outside of a ventilator, its parts or accessories <\/td>\n<\/tr>\n | ||||||
325<\/td>\n | Table 201.C.102 \u2014 Accompanying documents, general Table 201.C.103 \u2014 Instructions for use <\/td>\n<\/tr>\n | ||||||
330<\/td>\n | Table 201.C.104 \u2014 Technical description <\/td>\n<\/tr>\n | ||||||
331<\/td>\n | Annex D (informative) Symbols on marking Table 201.D.2.101 \u2014 Additional symbols on marking <\/td>\n<\/tr>\n | ||||||
333<\/td>\n | Annex AA (informative) Particular guidance and rationale <\/td>\n<\/tr>\n | ||||||
359<\/td>\n | Annex BB (informative) Data interface requirements <\/td>\n<\/tr>\n | ||||||
360<\/td>\n | Table BB.101 \u2014 Parameters and units of measurement Table BB.102 \u2014 Equipment identification <\/td>\n<\/tr>\n | ||||||
361<\/td>\n | Table BB.103 \u2014 Usage monitoring Table BB.104 \u2014 Equipment settings <\/td>\n<\/tr>\n | ||||||
364<\/td>\n | Table BB.105 \u2014 Ventilation monitoring <\/td>\n<\/tr>\n | ||||||
365<\/td>\n | Table BB.106 \u2014 Ventilator alarm limits <\/td>\n<\/tr>\n | ||||||
366<\/td>\n | Table BB.107 \u2014 Event information Table BB.108 \u2014Service monitoring <\/td>\n<\/tr>\n | ||||||
367<\/td>\n | Annex CC (informative) Reference to the IMDRF essential principles and labelling guidances <\/td>\n<\/tr>\n | ||||||
372<\/td>\n | Annex DD (informative) Reference to the essential principles Table DD.1 \u2014 Correspondence between this document and the essential principles <\/td>\n<\/tr>\n | ||||||
376<\/td>\n | Annex EE (informative) Reference to the general safety and performance requirements <\/td>\n<\/tr>\n | ||||||
380<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. Medical electrical equipment – Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients<\/b><\/p>\n |