{"id":395280,"date":"2024-10-20T04:18:10","date_gmt":"2024-10-20T04:18:10","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-2800-2022\/"},"modified":"2024-10-26T08:04:22","modified_gmt":"2024-10-26T08:04:22","slug":"ieee-2800-2022","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-2800-2022\/","title":{"rendered":"IEEE 2800 2022"},"content":{"rendered":"

This standard establishes the required interconnection capability and performance criteria for inverter-based resources interconnected with transmission and sub-transmission systems. Included in this standard are performance requirements for reliable integration of inverter-based resources into the bulk power system, including, but not limited to, voltage and frequency ride-through, active power control, reactive power control, dynamic active power support under abnormal frequency conditions, dynamic voltage support under abnormal voltage conditions, power quality, negative sequence current injection, and system protection. The standard shall also be applied to isolated inverter-based resources that are interconnected to an AC transmission system via a dedicated voltage source converter high-voltage direct current (HVDC-VSC) transmission facilities; in these cases, the standard shall apply to the combination of the isolated IBR and the HVDC-VSC facility and shall not apply to the isolated IBR unless they serve as a supplemental IBR device that is necessary for the IBR generating facility with HVDC-VSC to meet the requirements of this standard at the reference point of applicability. Purpose This standard provides uniform technical minimum requirements for the interconnection, capability, and performance of inverter-based resources interconnecting with transmission and sub-transmission systems. Abstract New IEEE Standard – Active – Draft. Uniform technical minimum requirements for the interconnection, capability, and lifetime performance of inverter-based resources interconnecting with transmission and sub-transmission systems are established in this standard. Included in this standard are performance requirements for reliable integration of inverter-based resources into the bulk power system, including, but not limited to, voltage and frequency ride-through, active power control, reactive power control, dynamic active power support under abnormal frequency conditions, dynamic voltage support under abnormal voltage conditions, power quality, negative sequence current injection, and system protection. The standard also applies to isolated inverter-based resources that are interconnected to an AC transmission system via dedicated voltage source converter high-voltage direct current (VSC-HVDC) transmission facilities; in these cases, the standard applies to the combination of the isolated IBRs and the VSC-HVDC facility, and not to an isolated IBR on its own.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
18<\/td>\nContents
\n 2 1. Overview
3 1.1 General <\/td>\n<\/tr>\n
19<\/td>\n4 1.2 Scope
5 1.3 Purpose
6 1.4 General remarks and limitations <\/td>\n<\/tr>\n
26<\/td>\n7 1.5 Word usage
8 2. Normative references <\/td>\n<\/tr>\n
27<\/td>\n9 3. Definitions, acronyms, and abbreviations
10 3.1 Definitions <\/td>\n<\/tr>\n
39<\/td>\n11 3.2 Acronyms and abbreviations <\/td>\n<\/tr>\n
41<\/td>\n12 4. General interconnection technical specifications and performance requirements
13 4.1 Introduction <\/td>\n<\/tr>\n
44<\/td>\n14 4.2 Reference points of applicability (RPA
15 4.3 Applicable voltages and frequency <\/td>\n<\/tr>\n
45<\/td>\n16 4.4 Measurement accuracy <\/td>\n<\/tr>\n
47<\/td>\n17 4.5 Operational measurement and communication capability
18 4.6 Control capability requirements <\/td>\n<\/tr>\n
48<\/td>\n19 4.7 Prioritization of IBR Responses
20 4.8 Isolation device
21 4.9 Inadvertent energization of the TS
22 4.10 Enter service <\/td>\n<\/tr>\n
50<\/td>\n23 4.11 Interconnection integrity
24 4.12 Integration with TS grounding <\/td>\n<\/tr>\n
51<\/td>\n25 5. Reactive Power\u2014Voltage Control Requirements within the Continuous Operation Region
26 5.1 Reactive power capability <\/td>\n<\/tr>\n
56<\/td>\n27 5.2 Voltage and reactive power control modes <\/td>\n<\/tr>\n
57<\/td>\n28 6. Active-Power \u2013 Frequency Response Requirements
29 6.1 Primary Frequency Response (PFR <\/td>\n<\/tr>\n
62<\/td>\n30 6.2 Fast Frequency Response (FFR <\/td>\n<\/tr>\n
68<\/td>\n31 7. Response to TS abnormal conditions
32 7.1 Introduction
33 7.2 Voltage <\/td>\n<\/tr>\n
80<\/td>\n34 7.3 Frequency <\/td>\n<\/tr>\n
83<\/td>\n35 7.4 Return to service after IBR plant trip <\/td>\n<\/tr>\n
84<\/td>\n36 8. Power quality
37 8.1 Limitation of voltage fluctuations induced by the IBR plant <\/td>\n<\/tr>\n
85<\/td>\n38 8.2 Limitation of harmonic distortion <\/td>\n<\/tr>\n
88<\/td>\n39 8.3 Limitation of overvoltage contribution <\/td>\n<\/tr>\n
90<\/td>\n40 9. Protection
41 9.1 Frequency Protection
42 9.2 Rate of Change of Frequency (ROCOF) Protection
43 9.3 AC Voltage Protection <\/td>\n<\/tr>\n
91<\/td>\n44 9.4 AC Overcurrent Protection
45 9.5 Unintentional Islanding Protection
46 9.6 Interconnection System Protection
10. Modeling Data <\/td>\n<\/tr>\n
93<\/td>\n2 11. Measurement data for performance monitoring and validation <\/td>\n<\/tr>\n
97<\/td>\n3 12. Test and verification requirements
4 12.1 Introduction
5 12.2 Definitions of verification methods <\/td>\n<\/tr>\n
100<\/td>\n6 12.3 Conformance verification framework <\/td>\n<\/tr>\n
107<\/td>\n7 Annex A (informative) Bibliography <\/td>\n<\/tr>\n
114<\/td>\n8 Annex B (informative) IBR interconnection examples
9 B.1 AC interconnection examples <\/td>\n<\/tr>\n
116<\/td>\n10 B.2 DC interconnection examples <\/td>\n<\/tr>\n
117<\/td>\n11 B.3 Complex IBR plant examples <\/td>\n<\/tr>\n
121<\/td>\n12 Annex C (informative) Inverter stability and system strength
13 C.1 Introduction to transmission connected inverter-based resources <\/td>\n<\/tr>\n
125<\/td>\n14 C.2 System strength and select metrics <\/td>\n<\/tr>\n
131<\/td>\n15 C.3 Inverter-based resource stability <\/td>\n<\/tr>\n
137<\/td>\n16 C.4 Grid forming inverters <\/td>\n<\/tr>\n
141<\/td>\n17 Annex D (informative) Illustration of voltage ride-through capability requirements
18 D.1 Interpretation of voltage ride-through capability requirements <\/td>\n<\/tr>\n
144<\/td>\n19 D.2 Informative figures for voltage ride-through capability requirements <\/td>\n<\/tr>\n
147<\/td>\n20 Annex E (informative) Recommended Practices for Voltage Harmonics of Inverter-Based Resources
21 E.1 Introduction <\/td>\n<\/tr>\n
150<\/td>\n22 E.2 Harmonic limits
23 E.3 Verification and Adherence Evaluation <\/td>\n<\/tr>\n
152<\/td>\n24 Annex F (informative) Guidance on Setting Protection with IBR
25 F.1 Frequency Protection
26 F.2 Rate of Change of Frequency (ROCOF) Protection
27 F.3 AC Voltage Protection <\/td>\n<\/tr>\n
153<\/td>\n28 F.4 AC Overcurrent Protection
29 F.5 Unintentional Islanding Protection <\/td>\n<\/tr>\n
154<\/td>\n30 F.6 Interconnection System Protection <\/td>\n<\/tr>\n
155<\/td>\n31 Annex G (informative) Recommendation for modeling data
32 G.1 General
33 G.2 Steady-state modeling data requirements <\/td>\n<\/tr>\n
157<\/td>\n34 G.3 Stability analysis dynamic modeling data requirements <\/td>\n<\/tr>\n
159<\/td>\n35 G.4 EMT dynamic modeling data requirements <\/td>\n<\/tr>\n
162<\/td>\n36 G.5 Power quality, Flicker and RVC modeling data requirements
37 G.6 Short circuit modeling data requirements <\/td>\n<\/tr>\n
164<\/td>\n38 Annex H (informative) Data that TS owner and TS operator may provide to the IBR developer
39 H.1 System Data <\/td>\n<\/tr>\n
166<\/td>\n40 H.2 Interconnection Ratings <\/td>\n<\/tr>\n
167<\/td>\n41 Annex I (informative) Illustration of Voltage Ride-Through Performance Requirements <\/td>\n<\/tr>\n
171<\/td>\n42 Annex J (informative) Type III WTG \u2013 challenges with controllability of negative-sequence current during
\n 43 unbalanced faults <\/td>\n<\/tr>\n
173<\/td>\nAnnex K (in 1 formative) Guidance on Fast Frequency Response (FFR
2 K.1 Introduction to FFR Variants
3 K.2 Variants of FFR <\/td>\n<\/tr>\n
176<\/td>\n4 K.3 Conditions for return to normal operations
5 K.4 Performance when returning to normal operations <\/td>\n<\/tr>\n
177<\/td>\n6 Annex L (informative) Damping ratio <\/td>\n<\/tr>\n
180<\/td>\n7 Annex M (Informative) Consecutive voltage deviation ride-through capability of isolated IBRs
\n 8 interconnected via VSC-HVDC <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE P2800\/D6.3, Dec 2021 – APPROVED DRAFT Standard for Interconnection and Interoperability of Inverter-Based Resources (IBR) Interconnecting with Associated Transmission Electric Power Systems<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2022<\/td>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":395289,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-395280","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/395280","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/395289"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=395280"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=395280"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=395280"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}