{"id":390923,"date":"2024-10-20T03:56:56","date_gmt":"2024-10-20T03:56:56","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-624842021-tc\/"},"modified":"2024-10-26T07:17:56","modified_gmt":"2024-10-26T07:17:56","slug":"bs-en-iec-624842021-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-624842021-tc\/","title":{"rendered":"BS EN IEC 62484:2021 – TC"},"content":{"rendered":"
IEC 62484:2020 defines the performance requirements of installed monitors used for the detection and identification of gamma emitters and the detection of neutron radiation emitters. These monitors are commonly known as spectrometric radiation portal monitors or SRPMs. They are used to monitor vehicles, cargo containers, people, or packages and are typically used at national and international border crossings and ports of entry. SRPMs may be used at any location where there is a need for this type of monitoring. This document establishes the general, radiological, climatic, mechanical, electric and electromagnetic and documentation requirements and associated test methods. A summary of the performance requirements and informative listing of environmental requirements from IEC 62706 is provided. This edition includes the following significant technical changes with respect to the previous edition: – title modified; – making the standard consistent with the new standards for detection of illicit trafficking of radioactive material (see the Introduction); – creating unformed functionality test for all environmental, electromagnetic and mechanical tests and a requirement for the coefficient of variation of each nominal mean reading;- reference to IEC 62706 for the environmental, electromagnetic and mechanical test conditions; – adding information regarding climatic exposures.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 30450586 <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | A-30373526 <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | Annex ZA (normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | INTRODUCTION Tables Table 1 \u2013 Standards for instrumentation used to detect illicittrafficking of radioactive and nuclear materials <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | 3 Terms and definitions, abbreviated terms and symbols, quantities and units 3.1 Terms and definitions <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | 3.2 Abbreviated terms and symbols <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | 3.3 Quantities and units 4 Design requirements 4.1 General 4.1.1 Overview <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | Figure 1 \u2013 Example of a two-sided system <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | Table 2 \u2013 Speed of moving sources Table 3 \u2013 Evaluation distances for different applications <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | 4.1.2 Pedestrian monitor 4.1.3 Road vehicle monitor 4.1.4 Rail vehicle monitor (includes rail transported containers) 4.1.5 Package (or conveyor) monitor 4.2 Physical configuration <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | 4.3 Spectral identification and count rate information 4.4 Indication features <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | 4.5 Occupancy and speed sensors 4.6 Markings 4.7 Protection of switches 4.8 Energy and count rate range 4.9 Data transfer 4.10 User interface 4.10.1 Audible (sound) alarm 4.10.2 Visual indicators <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | 4.10.3 Warning indicators 4.10.4 Basic controls and functions 4.10.5 Advanced indications and functions <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | 5 General test procedures 5.1 General test conditions 5.1.1 Nature of tests 5.1.2 Standard test conditions 5.1.3 Statistical fluctuations Table 4 \u2013 Standard test conditions <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | 5.2 Reference neutron radiation for alarm testing 5.3 Alarm categorization 5.4 General requirements for testing radionuclide identification ability <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | 5.5 Functionality test 5.5.1 General Table 5 \u2013 Test radionuclides Table 6 \u2013 Test materials1 <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | 5.5.2 Pre-test measurements 5.5.3 Intermediate (during test) measurements 5.5.4 Post-test measurements 6 Radiation detection requirements 6.1 Stability test 6.1.1 Requirements 6.1.2 Method of test Table 7 \u2013 Test result analysis <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | 6.2 Neutron radiation detection, if provided 6.2.1 Requirements 6.2.2 Method of test 6.3 Gamma over-range indication 6.3.1 Requirements 6.3.2 Method of test <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | 6.4 Detection of neutron radiation in a high gamma field 6.4.1 Requirements 6.4.2 Method of test \u2013 large road vehicle and multiple-sided rail vehicle monitors 6.4.3 Method of test \u2013 all other types of monitors 6.5 Background effects 6.5.1 Requirements <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | 6.5.2 Method of test 6.6 Radionuclide identification 6.6.1 Radionuclide library and identification categorization Table 8 \u2013 Radionuclide library Table 9 \u2013 Radionuclide categorisation <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | 6.6.2 Radionuclide identification qualification 6.6.3 Single radionuclide identification Table 10 \u2013 Identification acceptance criteria1,2 <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | 6.6.4 Simultaneous radionuclide identification <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | 6.6.5 Alarm without identification 7 Climatic requirements 7.1 General 7.2 Ambient temperature 7.2.1 Requirements 7.2.2 Method of test <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | 7.3 Relative humidity 7.3.1 Requirements 7.3.2 Method of test 7.4 Dust and moisture protection 7.4.1 Requirements 7.4.2 Method of test \u2013 Dust 7.4.3 Test method \u2013 Moisture <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | 7.5 Climatic exposure type test 7.5.1 Requirements 7.5.2 Method of test 8 Mechanical requirements 8.1 Vibration 8.1.1 Requirements 8.1.2 Method of test <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | 8.2 Microphonics\/Impact 8.2.1 Requirements 8.2.2 Method of test 9 Electric and electromagnetic requirements 9.1 Electrostatic discharge (ESD) 9.1.1 Requirements 9.1.2 Method of test 9.2 Radio frequency (RF) 9.2.1 Requirements 9.2.2 Method of test <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | 9.3 Radiated RF emissions 9.3.1 Requirements 9.3.2 Method of test 9.4 Conducted disturbances 9.4.1 Requirements 9.4.2 Method of test 9.5 Surges and oscillatory waves 9.5.1 Requirements 9.5.2 Method of test <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | 9.6 Line voltage and frequency fluctuations 9.6.1 Requirements 9.6.2 Method of test 10 Documentation 10.1 Operation and maintenance manual <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | 10.2 Test certificate 10.3 Declaration of conformity Table 11 \u2013 Summary of performance requirements \u2013 Informative <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | Table 12 \u2013 Environmental requirements \u2013 Informative1 <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | Annex A (informative)Identification of uranium and plutonium Table A.1 \u2013 Uranium and plutonium detection and identification guidance <\/td>\n<\/tr>\n | ||||||
114<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. Radiation protection instrumentation. Spectrometric radiation portal monitors (SRPMs) used for the detection and identification of illicit trafficking of radioactive material<\/b><\/p>\n |