{"id":254995,"date":"2024-10-19T16:51:12","date_gmt":"2024-10-19T16:51:12","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-13757-42013\/"},"modified":"2024-10-25T12:17:28","modified_gmt":"2024-10-25T12:17:28","slug":"bs-en-13757-42013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-13757-42013\/","title":{"rendered":"BS EN 13757-4:2013"},"content":{"rendered":"

This European Standard specifies the requirements of parameters for the physical and the link layer for systems using radio to read remote meters. The primary focus is to use the Short Range Device (SRD) unlicensed telemetry bands. The standard encompasses systems for walk-by, drive-by and fixed installations. As a broad definition, this European Standard can be applied to various application layers.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
6<\/td>\n1 Scope
2 Normative references
3 Terms, definitions and abbreviations
3.1 Terms and definitions <\/td>\n<\/tr>\n
7<\/td>\n3.2 Abbreviations <\/td>\n<\/tr>\n
8<\/td>\n4 General
4.1 Introduction <\/td>\n<\/tr>\n
9<\/td>\n4.2 Meter communications types <\/td>\n<\/tr>\n
12<\/td>\n4.3 Performance Classes <\/td>\n<\/tr>\n
13<\/td>\n5 Mode S
5.1 Mode S: General
5.2 Mode S: Transmitter <\/td>\n<\/tr>\n
14<\/td>\n5.3 Mode S: Receiver <\/td>\n<\/tr>\n
15<\/td>\n5.4 Mode S: Data encoding
5.4.1 Mode S: Manchester encoding
5.4.2 Mode S: Order of transmission of the encoded data
5.4.3 Mode S: Preamble and synchronisation pattern <\/td>\n<\/tr>\n
16<\/td>\n6 Mode T
6.1 Mode T: General
6.2 Mode T: Transmitter <\/td>\n<\/tr>\n
18<\/td>\n6.3 Mode T2 only: Receiver
6.4 Mode T: Data encoding
6.4.1 General
6.4.2 Mode T: Meter transmit: \u201c3 out of 6\u201d data encoding
6.4.2.1 General <\/td>\n<\/tr>\n
19<\/td>\n6.4.2.2 Mode T: Meter transmit: Order of transmission of the encoded data
6.4.2.3 Mode T1 and T2: Meter transmit: Preamble and synchronisation pattern <\/td>\n<\/tr>\n
20<\/td>\n6.4.3 Mode T2: Other Device transmit: Manchester encoding
6.4.3.1 General
6.4.3.2 Mode T2: Other Device transmit: Order of transmission of the encoded data
6.4.3.3 Mode T2: Other Device transmit: Preamble and synchronisation pattern
7 Mode R2
7.1 Mode R2: General
7.2 Mode R2: Transmitter <\/td>\n<\/tr>\n
22<\/td>\n7.3 R2: Receiver
7.4 Mode R2: Data encoding
7.4.1 Mode R2: Manchester encoding
7.4.2 Mode R2: Order of transmission of the encoded data
7.4.3 Mode R2: Preamble and synchronisation pattern <\/td>\n<\/tr>\n
23<\/td>\n8 Mode C
8.1 Mode C: General
8.2 Mode C: Transmitter <\/td>\n<\/tr>\n
24<\/td>\n8.3 Mode C: Receiver <\/td>\n<\/tr>\n
25<\/td>\n8.4 Mode C: Data encoding
8.4.1 General
8.4.2 Mode C: Preamble and synchronisation pattern <\/td>\n<\/tr>\n
26<\/td>\n9 Mode N
9.1 Mode N: General
9.2 Mode N: Physical link parameters <\/td>\n<\/tr>\n
28<\/td>\n9.3 Mode N: Receiver sensitivity
9.4 Mode N: Data encoding
9.4.1 Mode N: General
9.4.2 Mode N: Preamble and synchronisation pattern <\/td>\n<\/tr>\n
29<\/td>\n10 Mode F
10.1 Mode F: General
10.2 Mode F: Physical link parameters <\/td>\n<\/tr>\n
30<\/td>\n10.3 Mode F: Receiver sensitivity <\/td>\n<\/tr>\n
31<\/td>\n10.4 Mode F: Data encoding
10.4.1 Mode F: General
10.4.2 Mode F: Preamble and synchronisation pattern
11 Data Link Layer
11.1 General
11.2 Order of multi byte fields <\/td>\n<\/tr>\n
32<\/td>\n11.3 Frame format A
11.3.1 General
11.3.2 First block
11.3.3 Second block
11.3.4 Optional block(s)
11.4 Frame format B
11.4.1 General
11.4.2 First block <\/td>\n<\/tr>\n
33<\/td>\n11.4.3 Second block
11.4.4 Optional block
11.5 Field definitions
11.5.1 General
11.5.2 Multi byte fields
11.5.3 Length field (L-Field)
11.5.4 Control field (C-Field) <\/td>\n<\/tr>\n
35<\/td>\n11.5.5 Manufacturer ID (M-field) <\/td>\n<\/tr>\n
36<\/td>\n11.5.6 Address (A-field)
11.5.7 Cyclic redundancy check (CRC-field)
11.5.8 Control information field (CI-field)
11.6 Timing
11.6.1 Timing for installation messages <\/td>\n<\/tr>\n
37<\/td>\n11.6.2 Synchronous transmissions of meter messages <\/td>\n<\/tr>\n
38<\/td>\n11.6.3 Access timing
11.6.3.1 General
11.6.3.2 Mode R, S, T, C, N and F: Access to meter <\/td>\n<\/tr>\n
39<\/td>\n11.6.3.3 Frequent Access Cycle <\/td>\n<\/tr>\n
40<\/td>\n11.7 Repeated or duplicate messages
12 Connection to higher protocol layers
12.1 The Control Information Field (CI-field) <\/td>\n<\/tr>\n
42<\/td>\n12.2 CI \u2013fields for the Extended Link Layer
12.2.1 General
12.2.2 Communication Control Field (CC-field)
12.2.2.1 General <\/td>\n<\/tr>\n
43<\/td>\n12.2.2.2 Bi-directional Subfield (B-field)
12.2.2.3 Response Delay Subfield (D-field)
12.2.2.4 Synchronised Subfield (S-field)
12.2.2.5 Hop Count Subfield (H-field)
12.2.2.6 Priority Subfield (P-field)
12.2.2.7 Accessibility Subfield (A-field)
12.2.2.8 Repeated Access Subfield (R-field)
12.2.3 Access Number Field (ACC-field)
12.2.4 Manufacturer ID 2 (M2-field). <\/td>\n<\/tr>\n
44<\/td>\n12.2.5 Address 2 (A2-field)
12.2.6 Session Number Field (SN-field)
12.2.6.1 General
12.2.6.2 ENC-subfield
12.2.6.3 Time-subfield
12.2.6.4 Session-subfield <\/td>\n<\/tr>\n
45<\/td>\n12.2.6.5 Specification of a session
12.2.7 AES-128 Counter Mode Encryption
12.2.7.1 General
12.2.7.2 Manufacturer ID field (M-field)
12.2.7.3 Address field (A-field)
12.2.7.4 Communication Control Field (CC-field)
12.2.7.5 Session Number Field (SN-field)
12.2.7.6 Frame Number (FN) <\/td>\n<\/tr>\n
46<\/td>\n12.2.7.7 Block Counter (BC)
12.2.8 Payload Checksum Field (PayloadCRC-field)
12.3 CI-fields for the Transport Layer
12.3.1 General
12.3.2 Short Transport Layer
12.3.3 Long Transport Layer <\/td>\n<\/tr>\n
47<\/td>\nAnnex A (informative) Frequency allocation and band usage for the 868 MHz band <\/td>\n<\/tr>\n
48<\/td>\nAnnex B (informative) Flag, assignment of the \u201cunique User\/Manufacturer ID\u201d, three letter codes <\/td>\n<\/tr>\n
49<\/td>\nAnnex C (informative) Frame examples
C.1 Example of a frame from a meter in mode S
C.1.1 Conditions
C.1.2 Block content <\/td>\n<\/tr>\n
50<\/td>\nC.1.3 Bit string <\/td>\n<\/tr>\n
51<\/td>\nC.2 Example of a frame from a meter in mode T1
C.2.1 Condition
C.2.2 Block Content <\/td>\n<\/tr>\n
52<\/td>\nC.2.3 Bit string
C.3 Example of a frame from a meter in mode C1
C.3.1 Conditions <\/td>\n<\/tr>\n
53<\/td>\nC.3.2 Block content
C.3.3 Bit string <\/td>\n<\/tr>\n
55<\/td>\nAnnex D (informative) Example of predictive reception of synchronous messages <\/td>\n<\/tr>\n
56<\/td>\nAnnex E (informative) Timing diagrams <\/td>\n<\/tr>\n
67<\/td>\nAnnex F (informative) Counter Mode Flow <\/td>\n<\/tr>\n
68<\/td>\nAnnex G (informative) Structure of Extended Link Layer
CI-field = 8Ch
CI-field = 8Dh
CI-field = 8Eh
CI-field = 8Fh <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Communication systems for meters and remote reading of meters – Wireless meter readout (Radio meter reading for operation in SRD bands)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2013<\/td>\n72<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":254999,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[669,2641],"product_tag":[],"class_list":{"0":"post-254995","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-35-100-10","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/254995","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/254999"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=254995"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=254995"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=254995"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}