{"id":250226,"date":"2024-10-19T16:30:18","date_gmt":"2024-10-19T16:30:18","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iec-tr-616412014\/"},"modified":"2024-10-25T11:43:32","modified_gmt":"2024-10-25T11:43:32","slug":"bsi-pd-iec-tr-616412014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iec-tr-616412014\/","title":{"rendered":"BSI PD IEC\/TR 61641:2014"},"content":{"rendered":"
This technical report gives guidance on the method of testing of assemblies<\/span> under conditions of arcing in air due to an internal fault.<\/p>\n The purpose of this test is to assess the ability of the assembly<\/span> to limit the risk of personal injury, damage of assemblies<\/span> and its suitability for further service as a result of an internal arcing fault.<\/p>\n The test procedure given in this technical report applies only:<\/p>\n to enclosed, floor-standing or wall-mounted low-voltage switchgear and controlgear assemblies according to IEC 61439\u20112<\/span> <\/span> (power switchgear and controlgear assemblies – PSC assemblies<\/span>);<\/p>\n<\/li>\n<\/ul>\n This technical report can be used as a reference for arc fault tests of other products, but adaptations of the test procedures and acceptance criteria can apply taking into account the specifics of such other assemblies<\/span> or products.<\/p>\n<\/div>\n to situations when doors and covers of the assembly<\/span> are closed and correctly secured.<\/p>\n<\/li>\n<\/ul>\n When tests under different or more severe conditions are agreed between the user and the manufacturer, this technical report can be used as a guide.<\/p>\n The test procedure given in this technical report takes into consideration:<\/p>\n the effects of the internal overpressure acting on covers, doors, etc.;<\/p>\n<\/li>\n the thermal effects of the arc or its roots on the enclosures and of ejected hot gases and glowing particles.<\/p>\n<\/li>\n<\/ul>\n The test procedure given in this technical report does not cover:<\/p>\n other effects which can constitute a risk, such as toxic gases and loud noises;<\/p>\n<\/li>\n conditions during maintenance work, open doors or similar;<\/p>\n<\/li>\n access to the top and bottom of the assembly<\/span>.<\/p>\n<\/li>\n<\/ul>\n This is a voluntary test made at the discretion of the manufacturer.<\/p>\n Enclosed low-voltage switchgear and controlgear assemblies. Guide for testing under conditions of arcing due to internal fault<\/b><\/p>\n\n
\n
\n
\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 4<\/td>\n English
CONTENTS <\/td>\n<\/tr>\n\n 5<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 7<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 8<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 9<\/td>\n 3 Terms and definitions <\/td>\n<\/tr>\n \n 11<\/td>\n 4 Classification of low-voltage switchgear and controlgear assemblies
4.1 Classification with regard to the protection characteristic
4.2 Classification with regard to persons who have access <\/td>\n<\/tr>\n\n 12<\/td>\n 5 assembly characteristics
6 Requirements and tests for an arc ignition protected zone
6.1 Constructional requirements of an arc ignition protected zone <\/td>\n<\/tr>\n\n 13<\/td>\n 6.2 Dielectric test of arc ignition protected zones
6.3 IP test of arc ignition protected zones
7 Selection of test specimen and validity of tests for similar designs (possibilities for derivation) <\/td>\n<\/tr>\n\n 14<\/td>\n 8 Testing \u2013 Arc fault tests
8.1 General
8.2 Voltage <\/td>\n<\/tr>\n\n 15<\/td>\n 8.3 Current
8.4 Frequency
8.5 Duration of the test
8.6 Test procedure
8.6.1 Supply circuit
8.6.2 Arc initiation <\/td>\n<\/tr>\n\n 16<\/td>\n Tables
Table 1 \u2013 Sizes of the copper ignition wire without current-limiting protection device
Table 2 \u2013 Sizes of the copper ignition wire with current-limiting protection device <\/td>\n<\/tr>\n\n 17<\/td>\n 8.6.3 Repetition of the test
8.6.4 Indicators (for observing the thermal effects of gases) <\/td>\n<\/tr>\n\n 18<\/td>\n 8.7 Assessment of the test
9 Test report <\/td>\n<\/tr>\n\n 20<\/td>\n Figures
Figure 1 \u2013 Mounting frame for indicators
Figure 2 \u2013 Examples of installation positions of the indicators <\/td>\n<\/tr>\n\n 21<\/td>\n Annex\u00a0A (informative)User guide to arc fault mitigation
A.1 General <\/td>\n<\/tr>\n\n 22<\/td>\n A.2 Arc ignition protected zones
A.3 Items for classification
Table A.1 \u2013 Options for classification <\/td>\n<\/tr>\n\n 23<\/td>\n A.4 Use of this technical report <\/td>\n<\/tr>\n \n 24<\/td>\n Annex B (informative) List of notes concerning certain countries <\/td>\n<\/tr>\n \n 25<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2014<\/td>\n 28<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":250233,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[517,2641],"product_tag":[],"class_list":{"0":"post-250226","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-130-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/250226","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/250233"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=250226"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=250226"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=250226"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}