{"id":136217,"date":"2024-10-19T07:51:29","date_gmt":"2024-10-19T07:51:29","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/nfpa-701-15\/"},"modified":"2024-10-25T00:01:34","modified_gmt":"2024-10-25T00:01:34","slug":"nfpa-701-15","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/nfpa\/nfpa-701-15\/","title":{"rendered":"NFPA 701 15"},"content":{"rendered":"

Use NFPA 701 to evaluate textile materials used extensively in interior furnishing for public occupancy buildings. To help avoid devastating fires fueled by hanging textiles such as curtains and window shades, testing labs and manufacturers should reference the 2015 NFPA 701: Standard Methods of Fire Tests for Flame Propagation of Textiles and Films. Use the latest methods to assess the propagation of flame of various textiles and films under specified fire test conditions. NFPA 701’s test methods apply to curtains, window shades, draperies, table linens, textile wall hangings, as well as to fabrics used in the assembly of awnings, tents, tarps and other similar architectural fabric structures and banners. NFPA 701 spells out: Types of test apparatus Calibration of equipment Geometry and conditioning of specimens Testing and cleaning procedures This comprehensive document is essential for testing laboratories as well as fabric and textile product manufacturers. – See more at: http:\/\/catalog.nfpa.org\/2015-NFPA-701-Standard-Methods-of-Fire-Tests-for-Flame-Propagation-of-Textiles-and-Films-P1345.aspx#sthash.M8RB2wDQ.dpuf<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nImportant Notices and Disclaimers <\/td>\n<\/tr>\n
3<\/td>\nAdditional Notices and Disclaimers <\/td>\n<\/tr>\n
4<\/td>\n2.1 General
2.2 NFPA Publications <\/td>\n<\/tr>\n
8<\/td>\nChapter 1 Administration
1.1 Scope
1.2 Purpose
1.3 Units
Chapter 2 Referenced Publications <\/td>\n<\/tr>\n
9<\/td>\n2.3 Other Publications
2.4 References for Extracts in Mandatory Sections
Chapter 3 Definitions
3.1 General
3.2 NFPA Official Definitions
3.3 General Definitions
Chapter 4 General Requirements for Test Method 1
4.1 General
Chapter 5 Test Apparatus and Materials for Test Method 1
5.1 Conditioning Oven
5.2 Hood <\/td>\n<\/tr>\n
10<\/td>\n5.3 Test Chamber, Specimen Mounting Pin Bar, and Gas Burner
5.4 Gas and Control System
5.5 Mounting Jig
5.6 Timer
5.7 Balance
5.8 Ruler
5.9 Wire Brush <\/td>\n<\/tr>\n
11<\/td>\n5.10 Binder Clips
Chapter 6 Calibration and Standardization for Test Method 1
6.1 General
Chapter 7 Specimens and Conditioning for Test Method 1
7.1 Test Specimens
7.2 Conditioning
Chapter 8 Test Procedure for Test Method 1
8.1 Mounting of Test Specimens <\/td>\n<\/tr>\n
12<\/td>\n8.2 Burner Placement and Preparation
8.3 Conducting the Test
Chapter 9 Calculation of Results for Test Method 1
9.1 Calculation of Percent Mass Loss
Chapter 10 Flame Propagation Performance Criteria for Test Method 1
10.1 Performance Criteria
Chapter 11 General Requirements for Test Method 2
11.1 General <\/td>\n<\/tr>\n
13<\/td>\nChapter 12 Test Apparatus and Materials for Test Method 2
12.1 Conditioning Oven
12.2 Test Enclosure <\/td>\n<\/tr>\n
14<\/td>\n12.3 Restraining Clamps
12.4 Gas Burner
12.5 Timer
12.6 Ruler <\/td>\n<\/tr>\n
15<\/td>\nChapter 13 Specimens and Conditioning for Test Method 2
13.1 Test Specimens
13.2 Conditioning of Test Specimens <\/td>\n<\/tr>\n
16<\/td>\nChapter 14 Flame Test Procedures for Test Method 2
14.1 Mounting of Test Specimens
14.2 Conducting the Flame Test
14.3 Measurement of Length of Char
Chapter 15 Flame Propagation Performance Criteria for Test Method 2
15.1 Performance Criteria <\/td>\n<\/tr>\n
17<\/td>\n15.2 Retest
Chapter 16 Cleaning and Water Leaching Procedures
16.1 General
16.2 Application
16.3 Accelerated Dry Cleaning
16.4 Accelerated Laundering
16.5 Accelerated Water Leaching
Chapter 17 Reporting
17.1 General
17.2 Material Description
17.3 Conditioning
17.4 Test Conditions
17.5 Refurbishing or Weathering Conditions <\/td>\n<\/tr>\n
18<\/td>\n17.6 Test Results
17.7 Final Conclusion
Annex A Explanatory Material <\/td>\n<\/tr>\n
19<\/td>\nAnnex B Guidance on the Use of the Two Test Methods
Annex C Test Method 1 Information <\/td>\n<\/tr>\n
20<\/td>\nAnnex D Textile Considerations <\/td>\n<\/tr>\n
21<\/td>\nAnnex E Informational References <\/td>\n<\/tr>\n
22<\/td>\nIndex <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

NFPA 701: Standard Methods of Fire Tests for Flame Propagation of Textiles and Films<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
NFPA<\/b><\/a><\/td>\n2015<\/td>\n27<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":136222,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2638],"product_tag":[],"class_list":{"0":"post-136217","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-nfpa","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/136217","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/136222"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=136217"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=136217"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=136217"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}