ISO/TS 19930:2017
$36.40
Guidance on aspects of a risk-based approach to assuring sterility of terminally sterilized, single-use health care product that is unable to withstand processing to achieve maximally a sterility assurance level of 10-6
Published By | Publication Date | Number of Pages |
ISO | 2017-12 | 30 |
ISO/TS 19930:2017 provides guidance on identifying the aspects to be considered as part of a risk-based approach to selecting a sterility assurance level (SAL) for terminally sterilized, single-use health care product that is unable to withstand processing to achieve maximally a SAL of 10-6.
In addition, this document provides
a) background information on the assurance of sterility and sterility assurance level, and
b) guidance on strategies that can allow the achievement of a maximal SAL of 10-6.
ISO/TS 19930:2017 describes the elements of a quality management system which are applied to enable the appropriate selection of a SAL for terminally sterilized, single-use health care product that is unable to withstand processing to achieve maximally a SAL of 10-6.
NOTE It is not a requirement of the International Standards for development, validation and routine control of a sterilization process to have a full quality management system. Attention is drawn to the standard for quality management systems (see ISO 13485) that controls all stages of the lifecycle of health care product.
ISO/TS 19930:2017 is applicable to sterilization processes in which microorganisms are inactivated by physical and/or chemical means.
ISO/TS 19930:2017 does not apply
– to selecting a maximal SAL greater than 10-6 for health care product that is able to withstand processing to achieve maximally a SAL of 10-6;
– in cases where a maximal SAL of 10-6 is required and an alternative SAL is not allowed;
– in cases where a maximal SAL of greater than 10-6 (e.g. 10-3) has been accepted by regulatory authorities within their jurisdiction for health care product for defined use;
– to the sterilization of used or reprocessed health care product;
– to sterilization of health care product by filtration.
ISO/TS 19930:2017 does not describe detailed procedures for assessing microbial inactivation.
ISO/TS 19930:2017 does not specify requirements for the development, validation and routine control of a process for inactivating the causative agents of spongiform encephalopathies such as scrapie, bovine spongiform encephalopathy and Creutzfeldt-Jakob disease. Specific recommendations have been produced in particular countries for the processing of materials potentially contaminated with these agents.
NOTE See also ISO 22442-1, ISO 22442-2 and ISO 22442-3.
ISO/TS 19930:2017 does not supersede or modify published International Standards for particular sterilization processes. ISO/TS 19930:2017 neither recommends a SAL for a given health care product nor identifies a maximal SAL for a health care product to be labelled "sterile".
NOTE These are matters for regulatory authorities and can vary from country to country.