IEEE C37.04-2018

$91.54

IEEE Standard for Ratings and Requirements for AC High-Voltage Circuit Breakers with Rated Maximum Voltage Above 1000 V

Published By Publication Date Number of Pages
IEEE 2018 122
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Revision Standard – Active. The rating structure for all high-voltage circuit breakers, which include all voltage ratings above 1000 V ac and comprise both indoor and outdoor types, is covered in this standard. Preferred ratings are also provided. Typical circuit breakers covered by these standards have maximum voltage ratings ranging from 4.76 kV through 800 kV, and continuous current ratings of 600 A, 1200 A, 2000 A, 3000 A, and 4000 A associated with the various maximum voltage ratings. The rating structure establishes the basis for all assigned ratings, including continuous current, insulation capability (formerly dielectric withstand voltages), short-circuit current, transient recovery voltage, and capacitor switching, plus associated capabilities such as mechanical endurance, load current, and out-of-phase switching. Generator circuit breakers are covered by IEC/IEEE Std 62271-37-013.

PDF Catalog

PDF Pages PDF Title
1 IEEE Std C37.04™-2018 Front cover
2 Title page
4 Important Notices and Disclaimers Concerning IEEE Standards Documents
7 Introduction
8 Participants
10 Contents
12 1. Scope
2. Normative references
14 3. Definitions, acronyms, and abbreviations
3.1 Definitions
16 3.2 Acronyms and abbreviations
17 4. Service conditions
4.1 Usual service conditions
19 4.2 Unusual service conditions
20 5. Descriptions of ratings and capabilities
5.1 General
21 5.2 Rated maximum voltage (V) or (Ur)
5.3 Rated insulation capability
23 5.4 Rated power-frequency (fr)
5.5 Rated continuous (normal) current (Ir)
26 5.6 Rated short-circuit current and related required capabilities
29 5.7 Transient recovery voltage (TRV)
37 5.8 Rated capacitive current switching
39 5.9 Assigned out-of-phase switching current rating
40 5.10 Rated standard operating duty (standard duty cycle)
41 5.11 Rated control voltage
5.12 Rated operating pressure for insulation and/or interruption
5.13 Rated operating pressure for mechanical operation and special capabilities
42 6. Preferred ratings
6.1 General
44 6.2 Preferred maximum voltage and insulation capability ratings for circuit breakers
48 6.3 Preferred ratings for class S1 circuit breakers
53 6.4 Preferred ratings for class S2 circuit breakers for line systems below 100 kV 
59 6.5 Preferred ratings for circuit breakers 100 kV and above
70 6.6 Rated reclosing times for circuit breakers
6.7 Control voltage ranges for circuit breakers
72 6.8 Circuit breaker operation and operating endurance capabilities
73 7. Construction and functional components
7.1 Requirements for liquids in switchgear
74 7.2 Requirements for gases in circuit breakers
7.3 Grounding
7.4 Auxiliary and control equipment
76 7.5 Operating mechanisms
79 7.6 Alternative operating mechanisms
80 7.7 Low- and high-pressure interlocking and monitoring devices
7.8 Degrees of protection by enclosures
81 7.9 Enclosure and wiring requirements
7.10 Creepage distances
7.11 Gas and vacuum tightness
82 7.12 Liquid tightness
7.13 Noise requirements
84 7.14 Electromagnetic compatibility (EMC)
7.15 Vacuum interrupters and X-Ray emission
7.16 Radio influence voltage limits
85 7.17 Requirements for terminals and bushings used on outdoor or free standing circuit breakers
7.18 Circuit breaker mechanical loading
87 Pressurized components
7.20 Pressurized systems
88 7.21 Requirements for simultaneity of poles
8. Nameplate markings
8.1 Circuit breaker
89 8.2 External insulation
8.3 Operating mechanism
90 8.4 Current transformer and linear coupler nameplates
91 8.5 Accessories
8.6 Instructions and warning signs
9. Current transformers
9.1 General
9.2 Ratings
93 9.3 Polarity and lead marking
97 9.4 Undervoltage trip device
9.5 Specialized Applications
98 Annex A (informative) Bibliography
100 Annex B (informative) Transient recovery voltage (TRV)
114 Annex C (normative) Exposure to pollution
117 Annex D (informative) AC arc furnace switching
119 Annex E (informative) Free standing current transformers
121 Annex F (normative) Extended electrical endurance (class E2)
122 Back cover