IEEE 1812 2015
$48.75
IEEE Trial-Use Guide for Testing Permanent Magnet Machines
Published By | Publication Date | Number of Pages |
IEEE | 2015 | 56 |
New IEEE Standard – Active. Contained in this trial-use guide are instructions for conducting tests to determine the performance characteristics and machine parameters of permanent magnet (PM) machines. The tests described may be applied to motors and generators, as needed, and no attempt is made to partition this guide into clauses applying to motors and clauses applying to generators. It is not intended that this guide shall cover all possible tests, or tests of a research nature, but only those general methods that may be used to obtain the performance data and machine parameters. The schedule of factory and field tests, which may be required on new equipment, is normally specified by applicable standards or by contract specifications. This guide should not be interpreted as requiring any specific test in a given transaction or implying any guarantee as to specific performance indices or operating conditions. The term specified conditions for tests as used in this guide will be considered as rated conditions unless otherwise agreed upon. Rated conditions apply usually to the quantities listed on the machine nameplate.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std 1812-2014 Front cover |
3 | Title page |
5 | Important notices and disclaimers concerning IEEE standards documents |
8 | Participants |
10 | Introduction |
11 | Contents |
13 | Important notice 1. Overview 1.1 Scope 1.2 Purpose |
14 | 1.3 Organization of the guide 1.4 Instrumentation |
15 | 2. Normative references 3. Condition and integrity tests |
16 | 3.1 Resistance measurement 3.2 Phase sequence |
17 | 3.3 Insulation resistance 3.4 Dielectric and partial discharge tests 3.5 Polarity tests for magnets 3.6 Shaft and bearing current 3.7 Over-speed tests |
18 | 3.8 Resistance to demagnetization 3.9 Acoustic noise 3.10 Vibration 4. Steady-state tests 4.1 Introduction to steady-state tests 4.2 Open-circuit tests |
26 | 4.3 Short-circuit tests |
30 | 4.4 Load tests |
34 | 4.5 Thermal performance |
36 | 5. Transient tests 5.1 Retardation test |
39 | 5.2 Sudden short-circuit test |
41 | 6. Machine operating characteristics 6.1 Stator voltage waveform 6.2 Losses and efficiency |
45 | 6.3 Thermal capability 6.4 Torque ripple |
49 | Annex A (informative) Bibliography |
50 | Annex B (normative) Nomenclature |
51 | Annex C (informative) Background on demagnetization |
52 | C.1 Stator faults C.2 Asymmetric demagnetization |
53 | C.3 Detection of demagnetization C.4 Demagnetization due to temperature |
56 | Back cover |