DIN EN ISO 16911-2:2013 Edition

$50.70

Stationary source emissions – Manual and automatic determination of velocity and volume flow rate in ducts – Part 2: Automated measuring systems

Published By Publication Date Number of Pages
DIN 2013-06 63
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of EN ISO 16911 describes the quality assurance procedures related to Automated Measuring Systems (AMS) for the determination of the volumetric flow rate of flue gas, in order to meet the uncertainty requirements for measured values given by various regulations (e. g. Commission Decision of 18 July 2007). The calibration and validation of flow AMS are performed by parallel measurements with the reference manual method described in this standard, Part 1, EN ISO 16911-1. The purpose of this standard is to secure flow monitoring with a minimized uncertainty for use according to EU Directive 2000/76/EC, EU Directive 2001/80/EC and EU Directive 2010/75/EU. The purpose of this standard is also to secure flow monitoring with a total uncertainty equal to or less than stipulated in Commission Decision of 18 July 2007 and establishing guidelines for the monitoring and reporting of greenhouse gas emissions pursuant to Directive 2003/87/EC. The described method was validated in field trials at plants in Denmark and Germany.

DIN EN ISO 16911-2