This document refers to ISO 52018ā1.
ISO 52018ā1 gives a succinct enumeration of possible requirements related to thermal energy balance features and to fabric features. It also provides tables for regulators to report their choices in a uniform manner. This document provides many background considerations that can help both private actors and public authorities, and all stakeholders involved, to take informed decisions.
This document does not contain any normative provision.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
4 | European foreword |
5 | Endorsement notice |
9 | Foreword |
10 | Introduction |
12 | 1 Scope 2 Normative references 3 Terms and definitions 4 Symbols and subscripts |
13 | 5 General aspects |
14 | 6 Mix of EPB features with requirements 7 Summer thermal comfort 7.1 Motivation 7.2 Points of attention |
16 | 7.3 Indicators 7.4 Comparable economic strictness |
17 | 7.5 New construction/renovation 7.6 Exceptions 8 Winter thermal comfort 9 Energy need for heating, or variants 9.1 Motivation |
18 | 9.2 Indicators |
19 | 9.3 Comparable economic strictness |
20 | 9.4 New construction/renovation 9.5 Exceptions 10 Energy need for cooling, or variants 11 Combination of āneedsā |
21 | 12 Overall thermal insulation of the thermal envelope 12.1 Motivation 12.2 Indicators 12.3 Comparable economic strictness |
22 | 12.4 New construction/renovation 12.5 Intermediate forms between overall and individual thermal insulation 13 Thermal insulation of individual elements of the thermal envelope 13.1 Motivation |
23 | 13.2 Indicators 13.3 Points of attention |
25 | 13.4 Comparable economic strictness 13.5 New construction/renovation |
26 | 13.6 Exceptions 14 Thermal bridges 14.1 General 14.2 Motivation 14.3 Requirement setting |
27 | 14.4 Alternative routes |
28 | 14.5 New construction/renovation |
29 | 14.6 Further information 15 Window energy performance 15.1 Motivation 15.2 Indicators 15.3 Points of attention 15.4 New construction/renovation |
30 | 16 Airtightness 16.1 Motivation 16.2 Indicator and comparable economic strictness |
31 | 16.3 New construction/renovation 16.4 Measurement |
32 | 16.5 Further information |
33 | 17 Solar control |
34 | AnnexĀ A (informative) Input and method selection data sheetĀ āĀ Template |
35 | AnnexĀ B (informative) Input and method selection data sheetĀ āĀ Default choices |
37 | AnnexĀ C (informative) Regional references in line with ISO Global Relevance Policy |
38 | AnnexĀ D (informative) Example method for integrating fictitious cooling into the overall EPB indicators |
40 | AnnexĀ E (informative) Illustration of the variable value of the heating need per useful floor area for a given set of technical measures |
44 | AnnexĀ F (informative) An underpinning of an expression for the maximum mean thermal transmittance |
48 | Bibliography |