BS ISO 9869-2:2018+A1:2021
$167.15
Thermal insulation. Building elements. In-situ measurement of thermal resistance and thermal transmittance – Infrared method for frame structure dwelling
Published By | Publication Date | Number of Pages |
BSI | 2021 | 38 |
This document describes the infrared method for measuring the thermal resistance and thermal transmittance of opaque building elements on existing buildings when observing high emissivity diffuse surface using an infrared (IR) camera. This document demonstrates a screening test by quantitative evaluation to identify the thermal performance defect area of building elements.
This document aims to measure the thermal transmittance (U-value) of a frame structure dwelling with light thermal mass, typically with a daily thermal capacity calculated according to ISO 13786 below 30 kJ/(m2K).
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
6 | Foreword |
7 | Introduction |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 Symbols and units |
11 | 5 Principle |
12 | 6 Requirements for apparatus 6.1 General 6.1.1 Infrared camera. 6.1.2 Heat transfer coefficient sensor. 6.1.3 ET sensor. 6.1.4 Thermocouple thermometer. 6.1.5 Data logger. |
13 | 6.2 Infrared camera |
14 | 6.3 Heat transfer coefficient sensor 6.4 ET sensor 6.5 Thermocouple 6.6 Data logger 7 Measurement method 7.1 Building 7.2 Location of the measured area |
15 | 7.3 Measurement conditions 7.4 Measurement of heat transfer coefficient 7.5 Measurement of environmental temperature |
16 | 7.6 Surface temperature distribution of building elements 7.7 Measurement time and measurement interval 7.8 Measurement terms |
17 | 7.9 Measurement period 8 Calculations 8.1 Heat transfer area 8.2 Calculation of heat flow rate |
18 | 8.3 Calculation of thermal transmittance 9 Measurement accuracy 10 Test reports |
20 | Annex A (informative) Measurement principle |
24 | Annex B (informative) Calculation of environmental temperature, structure of ET sensor |
27 | Annex C (informative) Structure and calibration of heat transfer coefficient sensor |
31 | Annex D (informative) Uncertainty analysis |
33 | Annex E (informative) The calculation example of uncertainty analysis |
37 | Bibliography |