BS ISO 10916:2014
$215.11
Calculation of the impact of daylight utilization on the net and final energy demand for lighting
Published By | Publication Date | Number of Pages |
BSI | 2014 | 74 |
This International Standard defines the calculation methodology for determining the monthly and annual amount of usable daylight penetrating non-residential buildings through vertical facades and rooflights and the impact thereof on the energy demand for electric lighting. This International Standard can be used for existing buildings and the design of new and renovated buildings.
This International Standard provides the overall lighting energy balance equation relating the installed power density of the electric lighting system with daylight supply and lighting controls (proof calculation method).
The determination of the installed power density is not in the scope of this method, neither are controls relating, for instance, to occupancy detection. Provided the determination of the installed power density and control parameters using external sources, the internal loads by lighting and the lighting energy demand itself can be calculated. The energy demand for lighting and internal loads by lighting can then be taken into account in the overall building energy balance calculations:
-
heating;
-
ventilation;
-
climate regulation and control (including cooling and humidification);
-
heating the domestic hot-water supply of buildings.
For estimating the daylight supply and rating daylight-dependent artificial lighting control systems, a simple table-based calculation approach is provided. The simple method describes the division of a building into zones as required for daylight illumination-engineering purposes, as well as considerations on the way in which daylight supplied by vertical facade systems and rooflights is utilized and how daylight-dependent lighting control systems effect energy demand. Dynamic vertical facades with optional shading and light redirection properties are considered, i.e. allowing a separate optimization of facade solutions under direct insolation and under diffuse skies. For rooflighting systems standard, static solutions like shed rooflights and continuous rooflights are considered. The method is applicable for different latitudes and climates. For standard building zones (utilizations), operation times are provided.
For detailed computer-based analysis (comprehensive calculation), minimum requirements are specified.
To support overall building performance assessment, additional daylight performance indicators on the overall building level are provided.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | Foreword |
7 | Introduction |
9 | Section sec_1 Section sec_2 1 Scope 2 Normative references |
10 | Section sec_3 Section sec_3.1 Section sec_3.2 Section sec_3.3 Section sec_3.4 Section sec_3.5 Section sec_3.6 Section sec_3.7 3 Terms and definitions |
11 | Section sec_3.8 Section sec_3.9 Section sec_3.10 Section sec_3.11 Section sec_3.12 Section sec_3.13 Section sec_3.14 Section sec_3.15 Section sec_3.16 Section sec_4 4 Symbols, indices, and abbreviated terms |
12 | Section sec_4.1 4.1 Symbols |
13 | Section sec_4.2 Section sec_5 Section sec_5.1 4.2 Indices 5 Proof calculation method 5.1 Energy demand for lighting as function of daylight |
15 | Figure fig_1 Section sec_5.2 5.2 Subdivision of a building into zones |
16 | Section sec_5.3 Section sec_5.4 Section sec_5.5 Section sec_5.6 5.3 Operating time 5.4 Artificial lighting 5.5 Constant illuminance control 5.6 Daylight |
17 | Section sec_5.7 Section sec_6 5.7 Occupancy dependency factor FO,n 6 Daylight Performance Indicator |
18 | Annex sec_A Annex sec_A.1 Annex A (informative) Simple calculation method |
19 | Figure fig_A.1 |
20 | Figure fig_A.2 Annex sec_A.2 |
22 | Table tab_j Figure fig_A.3 Table tab_k Figure fig_A.4 |
23 | Table tab_l Figure fig_A.5 Annex sec_A.3 Annex sec_A.3.1 |
24 | Figure fig_A.6 |
25 | Figure fig_A.7 Figure fig_A.8 |
26 | Figure fig_A.9 |
28 | Table tab_A.1 Annex sec_A.3.2 |
29 | Annex sec_A.3.2.1 Figure fig_A.10 |
30 | Table tab_A.2 Annex sec_A.3.2.2 |
31 | Table tab_A.3 |
32 | Table tab_A.3___1 Annex sec_A.3.2.3 |
33 | Table tab_A.4 |
34 | Table tab_v Figure fig_A.11 Table tab_A.5 |
36 | Table tab_A.6 |
38 | Table tab_A.7 |
39 | Annex sec_A.3.2.4 Table tab_A.8 |
40 | Annex sec_A.4 |
41 | Annex sec_A.4.1 |
42 | Table tab_A.9 |
44 | Table tab_A.9___1 |
45 | Table tab_A.10 |
46 | Figure fig_A.12 Figure fig_A.13 Table tab_A.11 |
48 | Table tab_A.12 |
49 | Table tab_A.13 Annex sec_A.4.2 |
50 | Table tab_A.14 |
54 | Annex sec_A.5 |
55 | Table tab_A.15 Annex sec_A.6 |
56 | Table tab_A.16 Table tab_A.17 Annex sec_A.7 |
58 | Table tab_A.18 |
59 | Annex sec_A.8 Table tab_A.19 |
61 | Annex sec_B Annex B (normative) Comprehensive calculation |
62 | Annex sec_C Annex C (informative) Daylight performance indicator |
63 | Annex sec_D Annex sec_D.1 Figure fig_D.1 Annex D (informative) Examples |
64 | Table tab_D.1 |
65 | Table tab_D.2 |
66 | Annex sec_D.2 Annex sec_D.2.1 Figure fig_D.2 Annex sec_D.2.2 |
68 | Annex sec_D.2.3 |
70 | Table tab_D.3 Table tab_D.4 |
71 | Reference ref_1 Reference ref_2 Reference ref_3 Reference ref_4 Reference ref_5 Reference ref_6 Bibliography |