Shopping Cart

No products in the cart.

BS EN ISO 8655-6:2002 2009

$142.49

Piston-operated volumetric apparatus – Gravimetric methods for the determination of measurement error

Published By Publication Date Number of Pages
BSI 2009 26
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
5 TitlePage – Piston-operated volumetric apparatus�—
7 TableofContent – Contents Page
8 Foreword – Foreword
9 Introduction – Introduction
11 Scope – 1��� Scope
NormativeReference – 2��� Normative references
12 Clause1 – 4��� Apparatus
UntitledSubclause2 – 4.1��� Analytical balance or equivalent weighing device
UntitledSubclause2 – 4.2��� Liquid reservoir
UntitledSubclause2 – 4.3��� Weighing vessel
UntitledSubclause2 – 4.4��� Timing device
UntitledSubclause2 – 4.5��� Thermometer
UntitledSubclause2 – 4.6��� Hygrometer
UntitledSubclause2 – 4.7��� Barometer
Clause1 – 5��� Test liquid
Clause1 – 6��� Test conditions
Subclause2 – 6.1��� General
13 Subclause2 – 6.2��� Test room
Subclause2 – 6.3��� Evaporation
Subclause2 – 6.4��� Test cycle time
Clause1 – 7��� Procedure
Subclause2 – 7.1��� General
Subclause3 – 7.1.1��� Test volume
Subclause3 – 7.1.2��� Number of measurements per test volume
14 Subclause3 – 7.1.3��� Weighing procedure
Subclause3 – 7.1.4��� Test conditions during the weighing procedure
Subclause2 – 7.2��� Single-channel piston pipettes with air interface (in accordance with ISO�865…
UntitledSubclause3 – 7.2.1��� In the case of power-driven piston pipettes, aspiration and deliver…
UntitledSubclause3 – 7.2.2��� Place test liquid from the water container in the weighing vessel t…
UntitledSubclause3 – 7.2.3��� If using a variable-volume piston pipette, select the test volume; …
UntitledSubclause3 – 7.2.4��� Prepare the piston pipette and the test cycle as follows:
UntitledSubclause3 – 7.2.5��� Perform the following test cycle (see
15 UntitledSubclause3 – 7.2.6��� Repeat the test cycle described in
UntitledSubclause3 – 7.2.7��� Note the time to the nearest second taken to complete the 10�test c…
16 UntitledSubclause3 – 7.2.8��� After the last weighing of
UntitledSubclause3 – 7.2.9��� Measure the temperature of the remaining test liquid to the nearest
UntitledSubclause3 – 7.2.10��� The values obtained shall be evaluated in accordance with
Subclause2 – 7.3��� Multi-channel piston pipettes (in accordance with ISO�8655-2)
Subclause2 – 7.4��� Positive-displacement pipettes (in accordance with ISO�8655-2)
Subclause2 – 7.5��� Piston burettes (in accordance with ISO�8655-3)
Subclause3 – 7.5.1��� Preparation
Subclause3 – 7.5.2��� Test procedure
17 Subclause2 – 7.6��� Dilutors (in accordance with ISO�8655-4)
Subclause3 – 7.6.1��� General
Subclause3 – 7.6.2��� Preparation
Subclause3 – 7.6.3��� Test procedure
18 Subclause2 – 7.7��� Dispensers (in accordance with ISO�8655-5)
Subclause3 – 7.7.1��� Preparation
Subclause3 – 7.7.2��� Test procedure
Clause1 – 8��� Evaluation
Subclause2 – 8.1��� Calculation of mass loss
Subclause2 – 8.2��� Calculation of the corrected mass of each quantity delivered
19 Subclause2 – 8.3��� Conversion of the corrected mass to volume
Subclause2 – 8.4��� Systematic error of measurement
Subclause3 – 8.4.1��� Calculation
Subclause3 – 8.4.2��� Conformity evaluation
20 Subclause2 – 8.5��� Random error of measurement
Subclause3 – 8.5.1��� Calculation
Subclause3 – 8.5.2��� Conformity evaluation
Subclause2 – 8.6��� Uncertainty of measurement
Clause1 – 9��� Test report
22 AnnexNormative – Calculation of volumes from balance readings
23 AnnexInformative – Assessment of the uncertainty of the delivered volume
24 Bibliography – Bibliography
BS EN ISO 8655-6:2002 2009
$142.49