BS EN ISO 80601-2-90:2021

$215.11

Medical electrical equipment – Particular requirements for basic safety and essential performance of respiratory high-flow therapy equipment

Published By Publication Date Number of Pages
BSI 2021 100
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document applies to the basic safety and essential performance of ventilatory high-flow therapy equipment, as defined in 201.3.204, hereafter also referred to as ME equipment, in combination with its accessories: – intended for use in the home healthcare environment; – intended for use in professional healthcare facilities; – intended for use by a lay operator or a healthcare professional operator; – intended for use with patients who can breathe spontaneously; – intended for patients who would benefit from improved alveolar gas exchange; and who would benefit from receiving high-flow humidified respiratory gases, including a patient whose upper airway is bypassed; and EXAMPLE 1 Patients with Type 1 Respiratory Failure, which exhibits a reduction in arterial blood oxygenation or patients who would benefit from reduced work of breathing, as needed in Type 2 Respiratory Failure, where arterial carbon dioxide is high. – not intended for patients who are dependent on artificial ventilation for their life support. NOTE 1 In the home healthcare environment, the supply mains is often not reliable. Ventilatory high-flow therapy equipment is typically composed of four parts: 1) gas sources, – air, and – if needed, oxygen; NOTE 2 Gas sources include medical gas pipeline systems, gas cylinders, oxygen concentrators and ambient air. 2) humidifier; NOTE 3 When dry gas is utilized, a humidifier is typically needed. 3) breathing tube; 4) a patient interface, which is used to deliver gas to the patient; and 5) a flow controller, which is used to select and deliver the desired flow. NOTE 4 The flow controller can be at a fixed rate. NOTE 5 The flowrate range is dependent upon the intended patient population (e.g., neonatal, paediatric and adult patients can require different flowrates). These parts can be combined (e.g., the gas source and humidifier can be combined). Ventilatory highflow therapy equipment interfaces with the patient whose upper airway is intact via a nasal cannula or mask as well as a patient whose upper airway is bypassed via an endotracheal tube, oropharyngeal mask, or tracheostomy. Ventilatory high-flow therapy equipment can be transit-operable. This document is also applicable to those accessories intended by their manufacturer to be connected to the ventilatory high-flow therapy equipment, where the characteristics of those accessories can affect the basic safety or essential performance of the ventilatory high-flow therapy equipment. EXAMPLE 2 Breathing sets, connectors, water traps, expiratory valve, humidifier, breathing system filter, external electrical power source, distributed alarm system. This document does not specify the requirements for: – ventilators or accessories for ventilator-dependent patients intended for critical care applications, which are given in ISO 80601 2 12; – ventilators or accessories intended for anaesthetic applications, which are given in ISO 80601 2 13; – ventilators or accessories intended for the emergency medical services environment, which are given in ISO 80601 2 84; – ventilators or accessories intended for ventilator-dependent patients in the home healthcare environment, which are given in ISO 80601 2 72; – ventilatory support equipment or accessories intended for ventilatory impairment, which are given in ISO 80601 2 79; – ventilatory support equipment or accessories intended for ventilatory insufficiency, which are given in ISO 80601 2 80; – sleep apnoea therapy ME equipment, which are given in ISO 80601 2 70; – continuous positive airway pressure (CPAP) ME equipment; – high-frequency jet ventilators (HFJVs); – high-frequency oscillatory ventilators (HFOVs), which are given in ISO 80601 2 87; and – cuirass or “iron-lung” ventilation equipment. NOTE 4 Ventilatory high-flow therapy equipment can be incorporated into any of the above equipment, in which case those standards would be applicable for those ventilation-modes. This docum…..

PDF Catalog

PDF Pages PDF Title
2 undefined
5 Contents
8 Introduction
11 201. 1 Scope, object and related standards
201. 1.1 * Scope
12 201. 1.2 Object
13 201. 1.3 Collateral standards
201. 1.4 Particular standards
14 201. 2 Normative references
15 201. 3 Terms and definitions
20 201. 4 General requirements
201. 4.3 Essential performance
201.4.3.101 * Additional requirements for essential performance
201. 4.6 * ME equipment or ME system parts that contact the patient
21 201.4.11.101 * Additional requirements for pressurized gas input
201.4.11.101.1 Overpressure requirement
201.4.11.101.2 Compatibility requirement
22 201. 5 General requirements for testing of ME equipment
201. 5.101 * Additional requirements for the general requirements for testing of ME equipment
201.5.101.1 Respiratory high-flow therapy equipment test conditions
201.5.101.2 * Gas flowrate specifications
201.5.101.3 * Respiratory high-flow therapy equipment testing errors
23 201. 6 Classification of ME equipment and ME systems
201. 7 ME equipment identification, marking and documents
201.7.1.101 Information to be supplied by the manufacturer
201.7.2.4.101 Additional requirements for accessories
24 201. 7.2.18 External gas source
201. 7.4.3 Units of measurement
25 201.7.9.2.1 General
201.7.9.2.1.101 Additional general requirements
201.7.9.2.2.101 * Additional requirements for warnings and safety notices
27 201.7.9.2.8.101 * Additional requirements for start-up procedure
201.7.9.2.9.101 Additional requirements for operating instructions
201.7.9.2.9.101.1 Lay operator operating instructions
28 201.7.9.2.9.101.2 Healthcare professional operator operating instructions
201.7.9.2.12 Cleaning, disinfection and sterilization
29 201.7.9.2.13.101 Additional requirements for maintenance
201.7.9.2.14.101 Additional requirements for accessories, supplementary equipment, used material
201.7.9.3.1.101 * Additional general requirements
30 201.7.9.3.101 Additional requirements for the technical description
201. 8 Protection against electrical hazards from ME equipment
201. 9 Protection against mechanical hazards of ME equipment and ME systems
201.9.4.3.101 Additional requirements for instability from unwanted lateral movement
201.9.4.4 Grips and other handling devices
31 201.9.6.2.1.101 Additional requirements for audible acoustic energy
201. 10 Protection against unwanted and excessive radiation hazards
32 201. 11 Protection against excessive temperatures and other hazards
201.11.1.2.2 * Applied parts not intended to supply heat to a patient
201.11.2.2.1 Risk of fire in an oxygen rich environment
33 201.11.6.6 * Cleaning and disinfection of ME equipment or ME system
201.11.6.7 Sterilization of ME equipment or ME system
201. 11.7 Biocompatibility of ME equipment and ME systems
34 201. 11.8 Interruption of the power supply/supply mains to ME equipment
201.11.8.101 * Additional requirements for interruption of the power supply/supply mains to ME equipment alarm condition
201.11.8.101.1 Alarm conditions
35 201.11.8.101.2 Alternative power supply/supply mains
36 201. 12 Accuracy of controls and instruments and protection against hazardous outputs
201. 12.1 * Accuracy of controls and instruments
201.12.1.101 Continuous flow breathing-therapy mode
201.12.1.101.1 Flowrate accuracy
38 201.12.1.101.2 Accuracy of delivered oxygen concentration
40 201.12.2.101 Usability of ME equipment
201. 12.4 Protection against hazardous output
201.12.4.101 Oxygen monitor
41 201.12.4.102 * Maximum limited pressure protection device
201.12.4.103 Flowrate monitoring
42 201.12.4.104 Obstruction alarm condition
43 201. 12.101 * Protection against accidental adjustments
201. 13 Hazardous situations and fault conditions for ME equipment
201.13.2.101 * Additional specific single fault conditions
201.13.2.102 * Independence of delivery control function and related risk control measures
44 201.13.2.103 * Failure of one gas supply to respiratory high-flow therapy equipment
201. 14 Programmable electrical medical systems (PEMS)
201. 15 Construction of ME equipment
201. 15.101 Mode of operation
45 201. 15.102 Pre-use check
201. 15.103 Delivered oxygen concentration
201. 16 ME systems
46 201.16.1.101 Additional general requirements for ME systems
201. 16.2 * Accompanying documents of an ME system
201. 17 Electromagnetic compatibility of ME equipment and ME systems
201.101 Gas connections
201. 101.1 Breathing system connectors
201.101.1.1 * General
47 201.101.1.2 Other named ports
201.101.1.2.1 General
201.101.1.2.2 Patient-connection port
201.101.1.2.3 Accessory port
201.101.1.2.4 Monitoring probe port
48 201.101.1.2.5 Low-pressure oxygen inlet
201.101.1.2.6 Flow-direction-sensitive components
201.101.1.2.7 Nebulization port
201. 101.2 High-pressure oxygen inlet connector
49 201. 101.3 Gas intake port
201.102 Requirements for the breathing system and accessories
201. 102.1 * General
201. 102.2 Labelling
201. 102.3 Breathing sets
50 201. 102.4 * Humidification system
201. 102.5 Breathing system filter (BSF)
201. 102.6 Airway devices
201.103 * Indication of duration of operation
51 201.104 Functional connection
201. 104.1 General
201. 104.2 * Connection to an electronic health record
201. 104.3 * Connection to a distributed alarm system
201. 104.4 Connection for remote control
201.105 Power supply cords
52 201. 1.3 Collateral standards
201. 1.4 Particular standards
53 206 Usability
54 208 General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems
55 208.6.5.4.2 Selection of default alarm preset
208.6.12.2 * Operator alarm system logging
56 211 Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
211.7.4.7 Additional requirements for cleaning, disinfection and sterilization
57 211.10.1.1 General requirements for mechanical strength
Annexes
58 201. 1.3 Collateral standards
201. 1.4 Particular standards
64 Annex D (informative) Symbols on marking
65 Annex AA (informative) Particular guidance and rationale
AA.1 General guidance
AA.2 Rationale for particular clauses and subclauses
79 Annex BB (informative) Data interface requirements
BB.1 Background and purpose
80 BB.2 Data definition
83 Annex CC (informative) Reference to the IMDRF essential principles and labelling guidances
86 Annex DD (informative) Reference to the essential principles
89 Annex EE (informative) Reference to the general safety and performance requirements
92 Annex FF (informative) Terminology — Alphabetized index of defined terms