BS EN ISO 4064-2:2014
$215.11
Water meters for cold potable water and hot water – Test methods
Published By | Publication Date | Number of Pages |
BSI | 2014 | 112 |
This part of ISO 4064|OIML R 49 is applicable to the type evaluation and initial verification testing of water meters for cold potable water and hot water as defined in ISO 4064-1:2014|OIML R 49â1:2013. OIML Certificates of Conformity can be issued for water meters under the scope of the OIML Certificate System, provided that this part of ISO 4064|OIML R 49, ISO 4064-1:2014|OIML R 49â1:2013 and ISO 4064-3:2014|OIML R 49â3:2013 are used in accordance with the rules of the System.
This part of ISO 4064|OIML R 49 sets out details of the test programme, principles, equipment and procedures to be used for the type evaluation, and initial verification of a meter type.
The provisions of this part of ISO 4064|OIML R 49 also apply to ancillary devices, if required by national regulations.
The provisions include requirements for testing the complete water meter and for testing the measurement transducer (including the flow or volume sensor) and the calculator (including the indicating device) of a water meter as separate units.
PDF Catalog
PDF Pages | PDF Title |
---|---|
9 | Section sec_1 Section sec_2 1 Scope 2 Normative references |
10 | Section sec_3 Section sec_4 3 Terms and definitions 4 Reference conditions |
11 | Section sec_5 Section sec_6 Section sec_6.1 Section sec_6.2 Section sec_6.3 5 Symbols, units and equations 6 External examination 6.1 General 6.2 Object of the examination 6.3 Preparation |
12 | Section sec_6.4 Section sec_6.4.1 Section sec_6.4.2 Section sec_6.4.3 Section sec_6.4.3.1 Section sec_6.4.3.2 Section sec_6.4.3.3 6.4 Examination procedures |
13 | Section sec_6.4.3.4 Section sec_6.4.3.5 Section sec_6.4.3.5.1 Section sec_6.4.3.5.2 |
14 | Section sec_6.4.3.5.3 Section sec_6.4.3.6 Section sec_6.4.3.6.1 Section sec_6.4.3.6.2 Section sec_6.4.3.6.2.1 |
15 | Section sec_6.4.3.6.2.2 Section sec_6.4.3.6.2.3 |
16 | Section sec_6.4.4 Section sec_7 Section sec_7.1 Section sec_7.2 Section sec_7.2.1 Section sec_7.2.2 Section sec_7.2.2.1 7 Performance tests for all water meters 7.1 General 7.2 Required conditions for all tests |
17 | Section sec_7.2.2.2 Section sec_7.2.2.3 Section sec_7.3 Section sec_7.3.1 Section sec_7.3.2 Section sec_7.3.3 Section sec_7.3.3.1 Section sec_7.3.3.2 7.3 Static pressure test (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, 4.2.10) |
18 | Section sec_7.3.4 Section sec_7.4 Section sec_7.4.1 Section sec_7.4.2 Section sec_7.4.2.1 7.4 Determination of intrinsic errors (of indication) (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, 7.2.3) |
19 | Section sec_7.4.2.2 Section sec_7.4.2.2.1 Section sec_7.4.2.2.2 Section sec_7.4.2.2.3 |
20 | Section sec_7.4.2.2.4 Section sec_7.4.2.2.4.1 Section sec_7.4.2.2.4.2 Section sec_7.4.2.2.4.3 Section sec_7.4.2.2.4.4 Section sec_7.4.2.2.4.5 |
21 | Section sec_7.4.2.2.4.6 Section sec_7.4.2.2.5 Section sec_7.4.2.2.5.1 Section sec_7.4.2.2.5.2 Section sec_7.4.2.2.5.3 |
22 | Section sec_7.4.2.2.6 Section sec_7.4.2.2.6.1 Section sec_7.4.2.2.6.2 Section sec_7.4.2.2.7 Section sec_7.4.2.2.7.1 Section sec_7.4.2.2.7.2 Section sec_7.4.2.2.7.3 |
23 | Section sec_7.4.2.2.7.4 Section sec_7.4.2.2.7.5 |
24 | Section sec_7.4.3 Section sec_7.4.3.1 Section sec_7.4.3.2 Section sec_7.4.4 |
25 | Section sec_7.4.5 Section sec_7.4.6 Section sec_7.4.6.1 Section sec_7.4.6.2 Section sec_7.4.6.3 |
26 | Section sec_7.4.6.4 Section sec_7.5 Section sec_7.5.1 Section sec_7.5.2 Section sec_7.5.3 Section sec_7.5.4 Section sec_7.6 Section sec_7.6.1 Section sec_7.6.2 Section sec_7.6.3 7.5 Water temperature test (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, 4.2.8) 7.6 Overload water temperature test (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, 7.2.5) |
27 | Section sec_7.6.4 Section sec_7.7 Section sec_7.7.1 Section sec_7.7.2 Section sec_7.7.3 Section sec_7.7.4 Section sec_7.8 Section sec_7.8.1 7.7 Water pressure test (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, 4.2.8) 7.8 Reverse flow test (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, 4.2.7) |
28 | Section sec_7.8.2 Section sec_7.8.3 Section sec_7.8.3.1 Section sec_7.8.3.2 Section sec_7.8.3.3 |
29 | Section sec_7.8.4 Section sec_7.9 Section sec_7.9.1 Section sec_7.9.2 7.9 Pressure loss test (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, 6.5) |
30 | Table tab_b Figure fig_1 Section sec_7.9.3 Section sec_7.9.3.1 Section sec_7.9.3.2 |
32 | Table tab_c Figure fig_2 Section sec_7.9.4 Section sec_7.9.5 |
33 | Section sec_7.10 Section sec_7.10.1 Section sec_7.10.2 Section sec_7.10.3 Section sec_7.10.4 7.10 Flow disturbance tests (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, 6.3.4) |
34 | Section sec_7.11 Section sec_7.11.1 Section sec_7.11.2 Section sec_7.11.2.1 Section sec_7.11.2.2 Section sec_7.11.2.2.1 Section sec_7.11.2.2.2 Section sec_7.11.2.2.3 7.11 Durability tests (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, 7.2.6) |
35 | Section sec_7.11.2.2.4 Section sec_7.11.2.3 Section sec_7.11.2.3.1 Section sec_7.11.2.3.2 Section sec_7.11.2.3.3 Section sec_7.11.2.3.4 |
36 | Section sec_7.11.2.3.5 Section sec_7.11.2.3.6 Table tab_1 |
37 | Section sec_7.11.2.4 Section sec_7.11.2.4.1 Section sec_7.11.2.4.2 Section sec_7.11.3 Section sec_7.11.3.1 Section sec_7.11.3.2 Section sec_7.11.3.2.1 Section sec_7.11.3.2.2 |
38 | Section sec_7.11.3.2.3 Section sec_7.11.3.3 Section sec_7.11.3.3.1 Section sec_7.11.3.3.2 Section sec_7.11.3.3.3 Section sec_7.11.3.3.4 |
39 | Section sec_7.11.3.3.5 Section sec_7.11.3.4 Section sec_7.11.3.4.1 Section sec_7.11.3.4.2 Section sec_7.12 Section sec_7.13 Section sec_7.13.1 7.12 Magnetic field testing 7.13 Tests on ancillary devices of a water meter |
40 | Section sec_7.13.2 Section sec_7.13.3 Section sec_7.13.4 Section sec_7.14 Section sec_8 Section sec_8.1 Section sec_8.1.1 7.14 Environmental testing 8 Performance tests related to influence factors and disturbances 8.1 General requirements (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, A.1) |
41 | Section sec_8.1.2 Section sec_8.1.3 Section sec_8.1.4 Section sec_8.1.5 Section sec_8.1.6 |
42 | Section sec_8.1.7 Section sec_8.1.8 Section sec_8.1.8.1 |
43 | Section sec_8.1.8.2 Section sec_8.1.8.3 Section sec_8.1.8.4 |
44 | Section sec_8.1.8.5 Section sec_8.2 Section sec_8.2.1 Section sec_8.2.2 Section sec_8.2.3 8.2 Dry heat (non-condensing) (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, A.5) |
45 | Section sec_8.2.4 Section sec_8.3 Section sec_8.3.1 Section sec_8.3.2 Section sec_8.3.3 Section sec_8.3.4 8.3 Cold (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, A.5) |
46 | Section sec_8.4 Section sec_8.4.1 Section sec_8.4.2 Section sec_8.4.3 8.4 Damp heat, cyclic (condensing) (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, A.5) |
47 | Section sec_8.4.4 Section sec_8.5 Section sec_8.5.1 Section sec_8.5.2 Section sec_8.5.2.1 Section sec_8.5.2.2 Section sec_8.5.2.3 8.5 Power supply variation (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, A.5) |
48 | Figure fig_3 Section sec_8.5.2.4 |
49 | Section sec_8.5.3 Section sec_8.5.3.1 Section sec_8.5.3.2 Section sec_8.5.3.3 Section sec_8.5.3.4 Section sec_8.5.4 Section sec_8.5.4.1 |
50 | Section sec_8.5.4.2 Section sec_8.5.4.3 Section sec_8.6 Section sec_8.6.1 Section sec_8.6.2 Section sec_8.6.3 8.6 Vibration (random) (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, A.5) |
51 | Section sec_8.6.4 Section sec_8.7 Section sec_8.7.1 Section sec_8.7.2 Section sec_8.7.3 8.7 Mechanical shock (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, A.5) |
52 | Section sec_8.7.4 Section sec_8.8 Section sec_8.8.1 Section sec_8.8.2 Section sec_8.8.3 8.8 AC mains voltage dips, short interruptions and voltage variations (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, A.5) |
53 | Table tab_2 Table tab_3 Section sec_8.8.4 Section sec_8.9 Section sec_8.9.1 8.9 Bursts on signal lines (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, A.5) |
54 | Section sec_8.9.2 Section sec_8.9.3 Section sec_8.9.4 |
55 | Section sec_8.10 Section sec_8.10.1 Section sec_8.10.2 Section sec_8.10.3 Section sec_8.10.4 8.10 Bursts (transients) on AC and DC mains (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, A.5) |
56 | Section sec_8.11 Section sec_8.11.1 Section sec_8.11.2 Section sec_8.11.3 8.11 Electrostatic discharge (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, A.5) |
57 | Section sec_8.11.4 Section sec_8.12 Section sec_8.12.1 Section sec_8.12.2 Section sec_8.12.3 8.12 Radiated electromagnetic fields (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, A.5) |
59 | Table tab_4 Section sec_8.12.4 Section sec_8.13 Section sec_8.13.1 Section sec_8.13.2 Section sec_8.13.3 8.13 Conducted electromagnetic fields (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, A.5) |
60 | Table tab_5 Section sec_8.13.4 |
61 | Section sec_8.14 Section sec_8.14.1 Section sec_8.14.2 Section sec_8.14.3 8.14 Surges on signal, data and control lines (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, A.5) |
62 | Section sec_8.14.4 Section sec_8.15 Section sec_8.15.1 Section sec_8.15.2 Section sec_8.15.3 8.15 Surges on AC and DC mains power lines (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, A.5) |
63 | Section sec_8.15.4 Section sec_8.16 Section sec_8.16.1 Section sec_8.16.2 8.16 Static magnetic field (ISOÂ 4064-1:2014|OIMLÂ RÂ 49â1:2013, 7.2.8) |
64 | Section sec_8.16.3 Section sec_8.16.4 Section sec_8.16.5 Section sec_8.17 Section sec_8.17.1 Section sec_8.17.2 Section sec_8.17.3 8.17 Absence of flow test |
65 | Section sec_8.17.4 Section sec_9 Section sec_9.1 Section sec_9.2 Table tab_6 9 Test program for type evaluation 9.1 Number of samples required 9.2 Performance test applicable to all water meters |
66 | Section sec_9.3 Section sec_9.4 9.3 Performance tests applicable to electronic water meters, mechanical water meters fitted with electronic devices, and their separable parts 9.4 Type evaluation of separable parts of a water meter |
67 | Section sec_9.5 Section sec_10 Section sec_10.1 Section sec_10.1.1 Section sec_10.1.2 Section sec_10.1.3 9.5 Families of water meters 10 Tests for initial verification 10.1 Initial verification of complete and combined water meters |
68 | Section sec_10.1.4 Section sec_10.2 Section sec_10.2.1 10.2 Initial verification of separable parts of a water meter |
69 | Section sec_10.2.2 Section sec_10.2.3 Section sec_10.2.4 Section sec_11 Section sec_11.1 Section sec_11.2 Section sec_11.2.1 11 Presentation of results 11.1 Object of the reports 11.2 Identification and test data to be included in records |
70 | Section sec_11.2.2 |
71 | Annex sec_A Annex sec_A.1 Annex sec_A.2 Annex sec_A.3 Annex sec_A.3.1 Annex A (normative) Type examination and testing of checking facilities of electronic devices |
72 | Annex sec_A.3.2 Annex sec_A.3.2.1 Annex sec_A.3.2.2 Annex sec_A.3.2.2.1 |
73 | Annex sec_A.3.2.2.2 Annex sec_A.3.2.2.3 Annex sec_A.3.3 Annex sec_A.3.3.1 Annex sec_A.3.3.2 Annex sec_A.3.3.2.1 |
74 | Annex sec_A.3.3.2.2 Annex sec_A.3.4 Annex sec_A.3.4.1 Annex sec_A.3.4.2 |
75 | Annex sec_A.3.5 Annex sec_A.3.5.1 Annex sec_A.3.5.2 Annex sec_A.3.6 Annex sec_A.3.6.1 |
76 | Annex sec_A.3.6.2 |
77 | Annex sec_B Annex sec_B.1 Annex sec_B.2 Annex B (normative) Calculating the relative error (of indication) of a water meter |
78 | Annex sec_B.3 Annex sec_B.3.1 Annex sec_B.3.2 Annex sec_B.3.3 Annex sec_B.3.3.1 |
79 | Annex sec_B.3.3.2 Annex sec_B.3.3.3 |
80 | Annex sec_B.3.3.4 Annex sec_B.3.4 Annex sec_B.3.4.1 |
81 | Annex sec_B.3.4.2 Annex sec_B.3.4.3 |
82 | Annex sec_B.3.4.4 |
83 | Annex sec_C Annex C (normative) Installation requirements for flow disturbance tests |
84 | Table tab_v Figure fig_C.1 |
85 | Annex sec_D Annex sec_D.1 Annex sec_D.2 Annex sec_D.3 Annex D (normative) Type evaluation of a family of water meters |
86 | Figure fig_D.1 |
87 | Annex sec_E Table tab_w Figure fig_E.1 Annex E (informative) Examples of methods and components used for testing concentric water meters |
88 | Table tab_x Figure fig_E.2 |
89 | Table tab_y Figure fig_E.3 |
90 | Annex sec_F Annex sec_F.1 Annex sec_F.2 Annex F (informative) Determining the density of water |
91 | Annex sec_F.3 Table tab_F.1 |
92 | Annex sec_G Annex sec_G.1 Annex sec_G.2 Annex sec_G.3 Annex G (informative) Maximum uncertainties in the measurement of influence factors and disturbances |
93 | Annex sec_G.4 Annex sec_G.5 Annex sec_G.6 Annex sec_G.7 Annex sec_G.8 |
94 | Annex sec_G.9 Annex sec_G.10 |
95 | Annex sec_H Annex sec_H.1 Annex sec_H.2 Annex sec_H.3 Annex H (informative) Pressure loss test pressure tappings, hole and slot details |
96 | Table tab_an Figure fig_H.1 Table tab_ao Figure fig_H.2 |
97 | Table tab_ap Figure fig_H.3 |
98 | Annex sec_I Annex sec_I.1 Annex sec_I.2 Table tab_aq Figure fig_I.1 Annex I (normative) Flow disturbers |
99 | Table tab_ar Figure fig_I.2 Table tab_as Figure fig_I.3 |
100 | Table tab_I.1 Table tab_at Figure fig_I.4 |
101 | Table tab_I.2 Table tab_au Figure fig_I.5 |
102 | Table tab_I.3 Figure fig_I.6 Table tab_I.4 |
103 | Figure fig_I.7 Table tab_I.5 |
104 | Table tab_av Figure fig_I.8 Table tab_aw Figure fig_I.9 |
105 | Table tab_ax Figure fig_I.10 |
106 | Table tab_I.6 |
107 | Table tab_ay Figure fig_I.11 Table tab_I.7 |
108 | Figure fig_I.12 Table tab_I.8 |
109 | Reference ref_1 Reference ref_2 Reference ref_3 Reference ref_4 Reference ref_5 Reference ref_6 Reference ref_7 Reference ref_8 Reference ref_9 Reference ref_10 Reference ref_11 Reference ref_12 Bibliography |