Shopping Cart

No products in the cart.

BS EN IEC 62271-204:2022

$183.59

High-voltage switchgear and controlgear – Rigid gas-insulated transmission lines for rated voltage above 52 kV

Published By Publication Date Number of Pages
BSI 2022 60
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 62271 applies to rigid HV gas-insulated transmission lines (GIL) in which the insulation is obtained, at least partly, by a non-corrosive insulating gas, other than air at atmospheric pressure, for alternating current of rated voltages above 52 kV, and for service frequencies up to and including 60 Hz. It is intended that this international standard shall be used where the provisions of IEC 62271-203 do not cover the application of GIL (see Note 3). At each end of the HV gas-insulated transmission line, a specific element may be used for the connection between the HV gas-insulated transmission line and other equipment like bushings, power transformers or reactors, cable boxes, metal-enclosed surge arresters, voltage transformers or GIS, covered by their own specification. Unless otherwise specified, the HV gas-insulated transmission line is designed to be used under normal service conditions. Note 1 to entry: In this international standard, the term “HV gas-insulated transmission line” is abbreviated to “GIL”. Note 2 to entry: In this international standard, the word “gas” means gas or gas mixture, as defined by the manufacturer. Note 3 to entry: Examples of GIL applications are given: – where all or part of the HV gas-insulated transmission line is directly buried; or – where the HV gas-insulated transmission line is located, wholly or partly, in an area accessible to public; or – where the HV gas-insulated transmission line is long (typically longer than to 500 m) and the typical gas compartment length exceeds the common practice of GIS technology.

PDF Catalog

PDF Pages PDF Title
2 undefined
5 Annex ZA (normative)Normative references to international publicationswith their corresponding European publications
7 English
CONTENTS
8 FOREWORD
10 1 Scope
2 Normative references
11 3 Terms and definitions
13 4 Normal and special service conditions
14 5 Ratings
15 6 Design and construction
19 Table 1 – Second characteristic numeral of IP coding
26 7 Type tests
33 8 Routine tests
34 9 Guide to the selection of GIL (informative)
35 10 Information to be given with enquiries, tenders and orders (informative)
37 11 Transport, storage, installation, operating instructions and maintenance
43 12 Safety
44 13 Influence of the product on the environment
45 Annex A (informative) Estimation of continuous current
50 Annex B (informative) Earthing
53 Figure B.1 – Example of earthing system together with active anti-corrosion system in the case of solid bonding of the enclosure at both ends
54 Annex C (informative) Long-term testing of buried installations
56 Annex D (normative) Requirements for welds on pressurized parts
Table D.1 – Quantity of NDTs
57 Table D.2 – Acceptance criteria of imperfections
58 Bibliography
BS EN IEC 62271-204:2022
$183.59