Heat exchangers. Hydronic room fan coils units. Determination of the sound power level
Published By | Publication Date | Number of Pages |
BSI | 2015 | 26 |
This European Standard applies to hydronic fan coil units (FCU) as factory-made single assemblies which provide the functions of cooling and/or heating but do not include the source of cooling or heating.
The standard covers both air free delivery and air ducted units with a maximum external static pressure due to duct resistance of 120 Pa max.
This European Standard provides methods for the determination of the acoustical performance of fan coil units, defining standard working condition and installation.
It is not the purpose of this standard to specify the tests used for production or field testing.
For the purpose of remaining clauses, the term “unit” is used to mean “fan coil unit” as defined in 3.1 of EN 1397:2015 .
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | Contents Page |
5 | European foreword |
6 | 1 Scope 2 Normative references |
7 | 3 Terms and definitions 4 Measuring instruments |
8 | Table 1 — Uncertainties of measurement for indicated values 5 Operation of the unit |
9 | Figure 1 — Setup external static pressure difference of ducted units for other speeds 6 Installation 6.1 General 6.2 Non ducted units 6.2.1 General 6.2.2 Floor mounted unit |
10 | Figure 2 — Floor mounted unit with a closing plate between the feet 6.2.3 Wall mounted unit |
11 | Figure 3 — Example of installation low wall unit mounted on a frame, with the back plate 6.2.4 High wall mounted unit Figure 4 — Example of installation of high wall unit mounted on a frame |
12 | 6.2.5 Cassette and under ceiling mounted units Figure 5 — Example of installation of cassette unit mounted on a frame 6.2.6 Under floor mounted Figure 6 — Example of unit under floor mounted 6.3 Ducted units 6.3.1 General |
13 | 6.3.2 Discharge or inlet sides 6.3.2.1 General |
14 | Figure 7 — Duct termination flush to the wall Figure 8 — Open angle of 120 6.3.2.2 I-Y-H Type ducted units Figure 9 — I type ducted unit Figure 10 — H type ducted units |
15 | Figure 11 — H type ducted unit Figure 12 — Typical installation for the measurement of discharge sound level on the right side and free inlet + sound radiated by the casing on the left side |
16 | Figure 13 — Typical installation for the measurement of discharge sound level with ducted inlet Figure 14 — Typical installation for the measurement of inlet sound level with ducted discharge 6.3.2.3 U-type units |
17 | Figure 15 — U-type fan coil unit Figure 16 — Installation for the measurement of discharge sound level for U-type unit (and inlet + radiated) |
18 | Figure 17 — Installation for the measurement of inlet sound level for U-type unit (and discharge + radiated) 6.3.2.4 Units with lateral spigots Figure 18 — Installation for measurement of inlet sound level of units with lateral spigots (upper view) 6.3.2.5 Duct end correction |
19 | 6.3.3 Sound level radiated by the casing |
20 | Figure 19 — Installation of a U-type: noise radiated by the casing 7 Acoustic measurement 7.1 Frequency range 7.2 Acoustic standard 7.3 Diffuse field |
21 | 7.4 Free field Figure 20 — Screen to be used to simulate the wall 7.5 In-duct measurement 8 Uncertainty |
22 | 9 Test report 9.1 General information 9.2 Additional information 9.3 Test results |
23 | 10 Data to be recorded 11 Manufacturer’s data |
24 | Bibliography |