BS EN 16583:2015

$142.49

Heat exchangers. Hydronic room fan coils units. Determination of the sound power level

Published By Publication Date Number of Pages
BSI 2015 26
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard applies to hydronic fan coil units (FCU) as factory-made single assemblies which provide the functions of cooling and/or heating but do not include the source of cooling or heating.

The standard covers both air free delivery and air ducted units with a maximum external static pressure due to duct resistance of 120 Pa max.

This European Standard provides methods for the determination of the acoustical performance of fan coil units, defining standard working condition and installation.

It is not the purpose of this standard to specify the tests used for production or field testing.

NOTE

For the purpose of remaining clauses, the term “unit” is used to mean “fan coil unit” as defined in 3.1 of EN 1397:2015 .

PDF Catalog

PDF Pages PDF Title
4 Contents Page
5 European foreword
6 1 Scope
2 Normative references
7 3 Terms and definitions
4 Measuring instruments
8 Table 1 — Uncertainties of measurement for indicated values
5 Operation of the unit
9 Figure 1 — Setup external static pressure difference of ducted units for other speeds
6 Installation
6.1 General
6.2 Non ducted units
6.2.1 General
6.2.2 Floor mounted unit
10 Figure 2 — Floor mounted unit with a closing plate between the feet
6.2.3 Wall mounted unit
11 Figure 3 — Example of installation low wall unit mounted on a frame, with the back plate
6.2.4 High wall mounted unit
Figure 4 — Example of installation of high wall unit mounted on a frame
12 6.2.5 Cassette and under ceiling mounted units
Figure 5 — Example of installation of cassette unit mounted on a frame
6.2.6 Under floor mounted
Figure 6 — Example of unit under floor mounted
6.3 Ducted units
6.3.1 General
13 6.3.2 Discharge or inlet sides
6.3.2.1 General
14 Figure 7 — Duct termination flush to the wall
Figure 8 — Open angle of 120
6.3.2.2 I-Y-H Type ducted units
Figure 9 — I type ducted unit
Figure 10 — H type ducted units
15 Figure 11 — H type ducted unit
Figure 12 — Typical installation for the measurement of discharge sound level on the right side and free inlet + sound radiated by the casing on the left side
16 Figure 13 — Typical installation for the measurement of discharge sound level with ducted inlet
Figure 14 — Typical installation for the measurement of inlet sound level with ducted discharge
6.3.2.3 U-type units
17 Figure 15 — U-type fan coil unit
Figure 16 — Installation for the measurement of discharge sound level for U-type unit (and inlet + radiated)
18 Figure 17 — Installation for the measurement of inlet sound level for U-type unit (and discharge + radiated)
6.3.2.4 Units with lateral spigots
Figure 18 — Installation for measurement of inlet sound level of units with lateral spigots (upper view)
6.3.2.5 Duct end correction
19 6.3.3 Sound level radiated by the casing
20 Figure 19 — Installation of a U-type: noise radiated by the casing
7 Acoustic measurement
7.1 Frequency range
7.2 Acoustic standard
7.3 Diffuse field
21 7.4 Free field
Figure 20 — Screen to be used to simulate the wall
7.5 In-duct measurement
8 Uncertainty
22 9 Test report
9.1 General information
9.2 Additional information
9.3 Test results
23 10 Data to be recorded
11 Manufacturer’s data
24 Bibliography