Shopping Cart

No products in the cart.

BS EN 1646-1:2018 – TC:2020 Edition

$246.62

Tracked Changes. Leisure accommodation vehicles. Motor caravans – Habitation requirements relating to health and safety

Published By Publication Date Number of Pages
BSI 2020 96
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document specifies requirements intended to ensure the safety and health of persons when they use motor caravans for temporary or seasonal habitation. It also specifies the corresponding test methods. Specific requirements of this document apply to motor caravans where the overall length multiplied by the overall width does not exceed 13,5 m2 plan area. Requirements applicable to road safety are not included in the scope of this document. This document is applicable exclusively to motor caravans as defined in EN 13878.

PDF Catalog

PDF Pages PDF Title
52 undefined
59 1 Scope
2 Normative references
3 Terms and definitions
4 Testing
60 5 Design and construction
5.1 Occupancy
5.2 Entrance steps to living area
5.2.1 Heights
5.2.2 Minimum tread dimensions
5.2.3 Mechanical strength
5.2.4 Slip resistance test
5.2.4.1 Attachable or integral step
5.2.4.2 Separate entrance step
61 5.3 Doors
5.3.1 Dimensions
5.3.1.1 Motor caravans above 13,5 m2 plan area
5.3.1.2 Motor caravans equal to or less than 13,5 m2 plan area
5.3.2 Securing doors
5.3.3 Childproof locking systems
5.3.4 Dead-locking systems
5.4 Awning rails
6 Internal equipment
6.1 Bunks
6.1.1 Mattress and/or upholstery
6.1.2 Clearance
6.1.2.1 Motor caravans above 13,5 m2 plan area
62 6.1.2.2 Motor caravans equal to or below 13,5 m2 plan area
6.1.3 Protection against falling out
6.1.3.1 General
6.1.3.2 Rigid protection
6.1.3.3 Protection by curtains or nets
6.1.4 Mechanical strength
6.1.5 Security of bunks
63 6.1.6 Access to high level bunks
6.1.7 Protection against entrapment
6.2 Cupboards
6.3 Cooking appliance
64 7 Drinking water supply, storage and disposal of waste water
7.1 Couplings for drinking water supply
7.2 Drinking water
7.2.1 Tanks
7.2.2 Materials
7.2.3 Marking
7.3 Waste water disposal tank
7.4 Toilet waste disposal
7.4.1 Discharge systems
7.4.2 Outlets and couplings from toilet holding tanks
65 8 Appliances
8.1 Installation of appliances
8.2 Restriction concerning supply of appliances
9 Heating
66 10 Installations
10.1 Electricity
10.1.1 Low voltage
10.1.2 Extra low voltage
10.2 Liquefied petroleum gas (LPG)
11 Ventilation
11.1 General
11.2 Adjustment of ventilators
11.3 Location of ventilation openings
12 Fire precautions
12.1 Means of escape
12.1.1 Emergency exits
12.1.2 Escape path
67 12.1.3 Sanitation compartments
12.1.4 Emergency doors
12.1.5 Interior doors
12.1.6 Emergency windows and emergency panels
69 12.1.7 Work surfaces
12.1.8 Heating and cooking equipment
12.2 Protection of flammable elements
12.2.1 Rigid or guided elements
70 12.2.2 Non-guided elements
12.3 Hotplates
13 Warning notice
13.1 Provision of warning notice
13.2 Content of warning notice
71 14 User’s handbook
74 Annex A (normative)Strength of entrance step (see 5.3)
A.1 Principle
A.2 Preparation and procedure
A.3 Expression of results
75 A.4 Test report
76 Annex B (normative)Slip resistance test (see 5.2.4)
B.1 Principle
B.2 Preparation and procedure
77 B.3 Expression of results
B.4 Test Report
78 Annex C (normative)Separate entrance step stability test (see 5.2.4.2)
C.1 Principle
C.2 Preparation and procedure
79 C.3 Expression of results
C.4 Test report
80 Annex D (normative)Clear height over bunks (see 6.1.2)
D.1 Principle
D.2 Preparation and procedure
D.3 Expression of results
D.4 Test report
81 Annex E (normative)Strength of protection against falling out of bunks (see 6.1.3.3)
E.1 Principle
E.2 Preparation and procedure
E.3 Expression of results
E.4 Test report
82 Annex F (normative)Mechanical strength of bunks (see 6.1.4)
F.1 Principle
F.2 Selection of bunk
F.3 Preparation and procedure
F.4 Expression of results
F.5 Test report
84 Annex G (normative)Security of folding bunks (see 6.1.5)
G.1 Principle
G.2 Preparation and procedure
G.3 Expression of results
G.4 Test report
85 Annex H (normative)Safety of access to high level bunks (see 6.1.6)
H.1 Principle
H.2 Preparation and procedure
H.2.1 General
H.2.2 Attachment and deflection
H.3 Expression of results
H.4 Test report
87 Annex I (normative)Measurement of gaps (see 6.1.7)
I.1 Cone measuring device
I.2 Gaps in the base structure
88 I.3 Measurement of gaps
89 Annex J (normative)Heating (see Clause 9)
J.1 Principle
J.2 Preparation and procedure
J.3 Expression of results
90 J.4 Test report
91 Annex K (normative)Test equipment
K.1 General
K.2 Load measuring cell
K.3 Load measuring cell
K.4 Certified weights
K.5 Load spreading platform
K.6 Load spreading platform
K.7 Step testing device
92 K.8 Flexible load spreading device
K.9 Step testing plate
K.10 Friction test piece
93 K.11 Ball
K.12 Cone measuring device
94 Annex L (informative)Environmental aspects
BS EN 1646-1:2018 - TC
$246.62