ASME PTC 11 08:2008 Edition
$98.04
ASME PTC 11 Fans
Published By | Publication Date | Number of Pages |
ASME | 2008 | 178 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | CONTENTS |
5 | Figures |
6 | Tables |
7 | NOTICE |
8 | FOREWORD |
10 | COMMITTEE ROSTER |
12 | CORRESPONDENCE WITH THE PTC 11 COMMITTEE |
14 | 1 Object and Scope 1- 1 OBJECT 1- 1.1 Objectives 1- 1.2 Principal Quantities 1- 1.3 Additional Quantities 1- 1.4 Other Quantities 1- 2 SCOPE |
15 | 1- 3 APPLICABILITY 1- 4 UNCERTAINTY |
16 | 2 Definitions of Terms, Symbols, and Their Descriptions 2- 1 SYMBOLS |
21 | 2- 2 DEFINITIONS |
23 | 2-2.4-1 Typical Input and Outlet Boundaries |
24 | 2-2.4-2 Typical Input Power Boundaries |
28 | 3 Guiding Principles 3- 1 INTRODUCTION 3- 2 PRIOR AGREEMENTS 3- 3 CODE PHILOSOPHY 3- 3.1 Fan Performance |
31 | 3- 4 SYSTEM DESIGN CONSIDERATIONS 3- 5 INTERNAL INSPECTION AND MEASUREMENT OF CROSS SECTION |
32 | 3- 6 TEST PERSONNEL 3- 6.1 Test Team 3- 7 POINT OF OPERATION 3- 8 METHOD OF OPERATION DURING TEST 3- 8.1 Manual Mode Operation 3- 9 INSPECTION, ALTERATIONS, AND ADJUSTMENTS |
33 | 3- 10 INCONSISTENCIES 3- 11 MULTIPLE INLETS OR DUCTS 3- 12 PRELIMINARY TEST 3- 13 REFERENCE MEASUREMENTS |
35 | 4 Instruments and Methods of Measurement 4- 1 GENERAL CONSIDERATIONS 4- 1.1 Accuracy 4- 2 TRAVERSE SPECIFICATIONS 4- 2.1 Quantities Measured by Traverse |
37 | 4-2.2-1 Fan Room Pressure |
38 | 4-2.4-1 Sampling Point Details (Rectangular Duct) |
39 | 4-2.4-2 Sampling Point Details (Circular Duct) |
40 | 4-2.4-3 Number of Traverse Points |
41 | 4-2.5-1 Probe Orientation: Centrifugal Fans |
42 | 4- 3 BAROMETRIC PRESSURE 4-2.5-2 Probe Orientation: Axial Fans |
43 | 4- 4 TEMPERATURE 4- 4.1 Instruments 4- 4.5 Operation 4- 5 MOISTURE 4- 5.1 Instruments |
44 | 4- 6 GAS COMPOSITION 4- 6.1 Instruments 4- 7 PRESSURE SENSING |
45 | 4-7-1 Fechheimer Probe |
46 | 4-7-2 Five-Hole Probe |
47 | 4-7-3 Yaw and Pitch Planes 4-7-4 Yaw and Pitch Convention |
48 | 4-7.1-1 Five-Hole Probe Photos |
49 | 4-7.1-2 Prism Probe Cut-Away |
50 | 4-7.3-1 Free Stream Nozzle Jet 4-7.3-2 Wind Tunnel |
51 | 4-7.3-3 Free Stream |
53 | 4- 8 PRESSURE INDICATING 4- 8.1 Instruments |
54 | 4- 9 YAW AND PITCH 4- 9.1 Instruments |
55 | 4-9.3-1 Pitch Angle, Ф, Versus Pitch Coefficient, CФ |
56 | 4-9.3-2 Velocity Pressure Coefficient, Kv, Versus Pitch Pressure Coefficient, CФ 4-9.3-3 Total Pressure Coefficient, Kt, Versus Pitch Pressure Coefficient, CФ |
57 | 4- 10 ROTATIONAL SPEED 4- 10.1 Instruments 4- 11 INPUT POWER 4- 11.1 Instruments |
59 | 4-11.5-1 Summary of Instrumentation Requirements |
60 | 5 Computation of Results 5- 1 GENERAL CONSIDERATIONS 5- 2 CORRECTION OF TRAVERSE DATA |
62 | 5- 3 GAS COMPOSITION |
65 | 5- 4 DENSITY 5- 4.1 Atmospheric Air 5- 5 FLUID VELOCITY 5- 5.1 Point Velocities |
66 | 5- 6 MASS FLOW RATE 5- 6.1 Mass Flow Rate at Plane |
67 | 5- 7 FLOW- WEIGHTED AVERAGES |
68 | 5- 8 FAN INPUT POWER 5- 9 FAN SPEED ( SLIP METHOD) 5- 10 MASS FLOW RATE: SPECIFIC ENERGY APPROACH |
70 | 5- 11 VOLUME FLOW RATE: PRESSURE APPROACH |
72 | 5- 12 INLET FLOW DISTORTION |
74 | 5-12.7-1 Traverse Point Geometry |
75 | 5- 13 UNCERTAINTIES |
81 | 6 Report of Results 6- 1 GENERAL REQUIREMENTS 6- 2 EXECUTIVE SUMMARY 6- 3 INTRODUCTION 6- 4 CALCULATIONS AND RESULTS |
82 | 6- 5 INSTRUMENTATION 6- 6 CONCLUSIONS 6- 7 APPENDICES |
83 | 7 Uncertainty Analysis 7- 1 INTRODUCTION 7- 2 UNCERTAINTY PROPAGATION EQUATIONS |
84 | 7- 3 ASSIGNING VALUES TO PRIMARY UNCERTAINTIES |
86 | 7-3.2.2-1 Typical Values for Primary Systematic Uncertainty |
87 | 7- 4 FAN MASS FLOW AND UNCERTAINTY FOR MULTIPLE TRAVERSE PLANES |
88 | MANDATORY APPENDIX I REDUCED LOAD FAN INPUT POWER DETERMINATION Fig. I- 1 Preferred Point Locations Fig. I- 1 Preferred Point Locations |
89 | Fig. I- 2 Four- Point, Distance- Weighted Interpolation Method Fig. I- 2 Four- Point, Distance- Weighted Interpolation Method |
90 | NONMANDATORY APPENDICES A DATA SHEETS SAMPLE DATA SHEET DUCT MEASUREMENTS SAMPLE DATA SHEET DUCT MEASUREMENTS |
95 | B SAMPLE CALCULATIONS |
97 | Table B- 1F Unit Conversions and Constants Variable Formula/ Value Table B- 1F Unit Conversions and Constants Variable Formula/ Value Variable Formula/ Value Variable Formula/ Value |
101 | Table 8F Uncertainties in Atmospheric Mesurements Variable Table 8F Uncertainties in Atmospheric Mesurements Variable |
102 | Table B- 9F Systematic Uncertainties in Measurements Table B- 9F Systematic Uncertainties in Measurements Table B- 9F Random Uncertainties in Measurements Table B- 9F Random Uncertainties in Measurements |
104 | Variable Formula Variable Formula |
120 | Table B- 20F Calculations for Reference Measurements Table B- 20F Calculations for Reference Measurements |
122 | Table B- 21F Calculations for Gas Measurements at Plane 1A Table B- 21F Calculations for Gas Measurements at Plane 1A |
137 | C METHOD OF APPROACHING A SPECIFIED POINT OF OPERATION C- 1 INTRODUCTION C- 1 INTRODUCTION C- 2 FLOW MEASUREMENT C- 2 FLOW MEASUREMENT Fig. C- 2- 1 Typical Centrifugal Fan Arrangement Showing Flow and Differential Pressure Measurement Locations Fig. C- 2- 1 Typical Centrifugal Fan Arrangement Showing Flow and Differential Pressure Measurement Locations |
138 | Fig. C- 2- 2 Axial Fan Arrangement Showing Where Flow Rate Can Be Monitored Fig. C- 2- 3 Averaging Impact- Suction Flow- Monitoring Probe Fig. C- 2- 2 Axial Fan Arrangement Showing Where Flow Rate Can Be Monitored Fig. C- 2- 3 Averaging Impact- Suction Flow- Monitoring Probe |
139 | C- 2.1 Flow Calibration C- 2.1 Flow Calibration C- 3 TEST PROCEDURE C- 3 TEST PROCEDURE |
140 | Table C- 3- 1 Test Procedure Table C- 3- 1 Test Procedure |
141 | D DERIVATIONS OF UNCERTAINTIES EQUATIONS D- 1 UNCERTAINTY IN THE MASS FLOW RATE, D- 1 UNCERTAINTY IN THE MASS FLOW RATE, , AT PLANE , AT PLANE |
145 | D- 2 UNCERTAINTY IN D- 2 UNCERTAINTY IN , THE AVERAGE STATIC PRESSURE, AT PLANE , THE AVERAGE STATIC PRESSURE, AT PLANE |
146 | D- 3 UNCERTAINTY IN THE AVERAGE DENSITY, D- 3 UNCERTAINTY IN THE AVERAGE DENSITY, AT PLANE AT PLANE |
147 | D- 4 UNCERTAINTY IN THE AVERAGE SPECIFIC KINETIC ENERGY, D- 4 UNCERTAINTY IN THE AVERAGE SPECIFIC KINETIC ENERGY, , AT PLANE , AT PLANE |
149 | D- 5 UNCERTAINTY IN THE AVERAGE VELOCITY PRESSURE, D- 5 UNCERTAINTY IN THE AVERAGE VELOCITY PRESSURE, , AT PLANE , AT PLANE |
151 | D- 6 UNCERTAINTY IN THE AVERAGE TOTAL PRESSURE, D- 6 UNCERTAINTY IN THE AVERAGE TOTAL PRESSURE, , AT PLANE , AT PLANE |
152 | D- 7 UNCERTAINTY IN THE AVERAGE ABSOLUTE STATIC PRESSURE, D- 7 UNCERTAINTY IN THE AVERAGE ABSOLUTE STATIC PRESSURE, , AT PLANE , AT PLANE |
153 | D- 8 UNCERTAINTY IN THE INPUT POWER, D- 8 UNCERTAINTY IN THE INPUT POWER, , FOR A CALIBRATED AC MOTOR , FOR A CALIBRATED AC MOTOR D- 9 UNCERTAINTY IN THE FAN MEAN DENSITY, D- 9 UNCERTAINTY IN THE FAN MEAN DENSITY, |
154 | D- 10 UNCERTAINTY IN THE FAN SPECIFIC ENERGY, D- 10 UNCERTAINTY IN THE FAN SPECIFIC ENERGY, |
157 | D- 11 UNCERTAINTY IN THE FAN OUTPUT POWER, D- 11 UNCERTAINTY IN THE FAN OUTPUT POWER, |
164 | D- 12 UNCERTAINTY IN THE FAN VOLUME FLOW RATE, D- 12 UNCERTAINTY IN THE FAN VOLUME FLOW RATE, |
170 | D- 13 UNCERTAINTY IN THE FAN OUTPUT POWER, D- 13 UNCERTAINTY IN THE FAN OUTPUT POWER, |
176 | E REFERENCES AND FURTHER READING E- 1 REFERENCES E- 1 REFERENCES |
177 | E- 2 FURTHER READING E- 2 FURTHER READING |