Shopping Cart

No products in the cart.

ASHRAE Book ThermalGuidelines 2024 5ed

$44.96

Thermal Guidelines for Data Processing Environments, Fifth Edition, Revised and Expanded

Published By Publication Date Number of Pages
ASHRAE 2024 178
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Thermal Guidelines for Data Processing Environments provides groundbreaking, vendor-neutral information that empowers data center designers, operators, and managers to better determine the impacts of varying design and operation parameters on information technology equipment (ITE). This book covers six primary areas:

PDF Catalog

PDF Pages PDF Title
1 ASHRAE TC 9.9 Reference Card
14 Contents
18 Preface to the Revised and Expanded Fifth Edition
20 Acknowledgments
22 1Introduction
23 1.1 BOOK FLOW
24 1.2 PRIMARY USERS OF THIS BOOK
25 1.3 ADOPTION
1.4 DEFINITIONS
30 2Environmental Guidelines for Air-Cooled Equipment
2.1 BACKGROUND
32 2.2 NEW AIR-COOLED EQUIPMENT ENVIRONMENTAL SPECIFICATIONS
46 2.3 GUIDE FOR THE USE AND APPLICATION OF THE ASHRAE DATA CENTER CLASSES
48 2.4 SERVER METRICS TO CONSIDER IN USING GUIDELINES
62 3Environmental Guidelines forLiquid-Cooled Equipment
63 3.1 ITE LIQUID COOLING
67 3.2 FACILITY WATER SUPPLY TEMPERATURE CLASSES FOR ITE
70 4Facility Temperature and Humidity Measurement
71 4.1 FACILITY HEALTH AND AUDIT TESTS
74 4.2 EQUIPMENT INSTALLATION VERIFICATION TESTS
75 4.3 EQUIPMENT TROUBLESHOOTING TESTS
77 4.4 COOLING SIMULATION
78 5Equipment Placement and Airflow Patterns
5.1 EQUIPMENT AIRFLOW
80 5.2 EQUIPMENT ROOM AIRFLOW
86 6Equipment Manufacturers’ Heat and Airflow Reporting
6.1 PROVIDING HEAT RELEASE AND AIRFLOW VALUES
87 6.2 EQUIPMENT THERMAL REPORT
89 6.3 EPA ENERGY STAR REPORTING
92 Appendix A2021 ASHRAE EnvironmentalGuidelines for ITE—Expanding the Recommended Environmental Envelope
95 A.1 DRY-BULB TEMPERATURE LIMITS
97 A.2 MOISTURE LIMITS
101 A.3 ACOUSTICAL NOISE LEVELS
102 A.4 DATA CENTER OPERATION SCENARIOS FOR THE RECOMMENDED ENVIRONMENTAL LIMITS
104 Appendix B2021 Air-Cooled Equipment Thermal Guidelines (I-P)
110 Appendix CDetailed Flowchart for the Use and Application of the ASHRAE Data Center Classes
116 Appendix DESD Research and Static Control Measures
D.1 ESD BACKGROUND
D.2 ESD RESEARCH
123 D.3 PERSONNEL AND OPERATIONAL ISSUES
D.4 FLOORING ISSUES
124 D.5 FURTHER READING
126 Appendix EResearch on the Effect of RH and Gaseous Pollutants on ITE Reliability
129 E.1 CONCLUSIONS FROM THE RESEARCH
132 Appendix FPsychrometric Charts
138 Appendix GAltitude Derating Curves
140 Appendix HPractical Example of the Impact of Compressorless Cooling on Hardware Failure Rates
144 Appendix IITE Reliability Data for Selected Major U.S. and Global Cities
145 I.1 NOTES ON FIGURES AND TABLES
160 Appendix JOSHA and Personnel Working in High Air Temperatures
164 Appendix KAllowable Server Inlet Temperature Rate of Change
168 Appendix LAllowable Server Inlet RH Limits versus Maximum Inlet Dry-Bulb Temperature
172 References and Bibliography
ASHRAE Book ThermalGuidelines 2024 5ed