Shopping Cart

No products in the cart.

AAMI 60601 2 19 2009 RA 2014 A1 2016

$115.49

ANSI/AAMI/IEC 60601-2-19:2009/(R)2014 & A1:2016 – Medical Electrical Equipment-Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators

Published By Publication Date Number of Pages
AAMI 2009 58
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This standard applies to the basic safety and essential performance of baby incubators. This standard can also be applied to baby incubators used for compensation or alleviation of disease, injury or disability. This standard does not apply to heating devices intended for physiotherapy, radiant warmers, and transport incubators.

PDF Catalog

PDF Pages PDF Title
1 ANSI/AAMI/IEC 60601-2-19:2009,
Medical Electrical Equipment —
Part 2-19: Particular requirements for the basic safety
and essential performance of infant incubators
2 Objectives and uses of AAMI standards and recommended practices
3 Title page
4 AAMI Standard
Copyright information
5 CONTENTS
6 Glossary of equivalent standards
8 Committee representation
9 Background of ANSI/AAMI adoption of IEC 60601-2-19:2009
10 FOREWORD
12 INTRODUCTION
13 201.1 Scope, object and related standards
201.1. 1 Scope
14 201.1. 2 Object
201.1.3 * Collateral standards
201.1. 4 Particular standards
15 201.2 Normative references
201.3 Terms and definitions
17 201.4 General requirements
18 201.4.1 Conditions for application to ME EQUIPMENT or ME SYSTEMS
201.4.3 * ESSENTIAL PERFORMANCE
201.4.3.101 ESSENTIAL PERFORMANCE of INFANT INCUBATORS
201.5 General requirements for testing ME EQUIPMENT
19 201.6 Classification of ME EQUIPMENT and ME SYSTEMS
201.7 ME EQUIPMENT identification, marking and documents
201.7.2.101 * Oxygen monitor
201.7.2.102 Heater surface temperature
201.7.4 Markings of controls and instruments (see also Table C.3 of the general standard)
201.7.4.2 * Control devices
20 201.7.9.2.2 * Warning and safety notices
201.7.9.2.8 * Start-up PROCEDURE
201.7.9.2.9 * Operating instructions
21 201.7.9.3 Technical description
201.7.9.3.1 General
201.8 Protection against electrical HAZARDS from ME EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS of ME EQUIPMENT and ME SYSTEMS
201.9.2 HAZARDS associated with moving parts
201.9.2.1 General
201.9.6.2 Acoustic energy
201.9.6.2.1 Audible acoustic energy
201.9.6.2.1.101 * Sound level within the COMPARTMENT
201.9.6.2.1.102 * Audible alarm sound level
22 201.9.6.2.1.103 * Audible alarms sound level within compartment
201.9.8 HAZARDS associated with support systems
201.9.8.3 Strength of PATIENT or OPERATOR support or suspension system
201.9.8.3.1 General
201.9.8.3.101 * Barriers
201.9.8.3.102 MATTRESS tray
23 201.9.8.101 Supports and mounting brackets for ACCESSORIES
201.10 Protection against unwanted and excessive radiation HAZARDS
201.11 Protection against excessive temperatures and other hazards
201.11.1 Excessive temperature in ME EQUIPMENT
201.11.1.2.2 APPLIED PARTS not intended to supply heat to a PATIENT
24 201.11.2 * Fire prevention
201.11.6.2 * Overflow in ME EQUIPMENT
201.11.6.3 Spillage on ME EQUIPMENT and ME SYSTEMS
201.11.6.6 *Cleaning and disinfection of ME EQUIPMENT and ME SYSTEMS
201.11.8 Interruption of the power supply / SUPPLY MAINS to ME EQUIPMENT
25 201.12 Accuracy of controls and instruments and protection against hazardous outputs
201.12.1 Accuracy of controls and instruments
201.12.1.101 * Stability of INCUBATOR TEMPERATURE
201.12.1.102 * Uniformity of INCUBATOR TEMPERATURE
201.12.1.103 * Accuracy of SKIN TEMPERATURE SENSOR
26 201.12.1.104 * Accuracy between SKIN TEMPERATURE and CONTROL TEMPERATURE
201.12.1.105 * Accuracy of INCUBATOR TEMPERATURE indication
201.12.1.106 * Accuracy of INCUBATOR TEMPERATURE control
201.12.1.107 * Warm-up time
27 201.12.1.108 * Overshoot of INCUBATOR TEMPERATURE
201.12.1.109 * Accuracy of indication of relative humidity
201.12.1.110 * Oxygen control
201.12.1.111 * Air velocity
28 201.12.1.112 * Weighing scale
201.12.2 Usability
201.12.2.101 * Indication of SKIN TEMPERATURE
29 201.12.2.102 * Indication of the mode of operation
201.12.2.103 Temperature control
201.12.3 Alarm systems
201.12.3.101 * Air circulation fan
201.12.3.102 * Connector to SKIN TEMPERATURE SENSOR
30 201.12.3.103 Alarm for interruption of power supply
201.12.3.104 AUDIO PAUSED of audible alarm
201.12.3.105 Alarm function test
201.12.4.2 Indication of parameters relevant to safety
201.12.4.2.101 * CO2-concentration
31 201.13 HAZARDOUS SITUATIONS and fault conditions
201.13.2.6 * Leakage of liquid
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.15.3 Mechanical strength
201.15.3.5 Rough handling test
32 201.15.3.101 Access to INFANT
201.15.4.1 Construction of connectors
201.15.4.1.101 * Temperature sensors
201.15.4.2 Temperature and overload control devices
201.15.4.2.1 Application
34 201.15.4.2.2 Temperature settings
201.15.4.2.2.101 * AIR CONTROLLED INCUBATOR range
201.15.4.2.2.102 * BABY CONTROLLED INCUBATOR range
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS
202 Electromagnetic compatibility – Requirements and test
202.6.2.3 Radiated RF electromagnetic fields
202.6.2.3.1 Requirements
35 210 Requirements for the development of physiologic closed-loop controllers
Annexes
36 Annex AA (informative) Particular guidance and rationale
Subclause 201.1.3 – Collateral standards
Subclause 201.4.3 – ESSENTIAL PERFORMANCE
37 Subclause 201.5.3 a) – Ambient temperature, humidity, atmospheric pressure
Subclause 201.7.2.101 – Oxygen monitor
Subclause 201.7.4.2 – Control devices
Subclause 201.7.9.2.2 – Warnings and safety notices
Subclause 201.7.9.2.8 – Start-up PROCEDURE
38 Subclause 201.7.9.2.9 – Operating instructions
Subclause 201.9.6.2.1.101 – Sound level within the COMPARTMENT
Subclause 201.9.6.2.1.102 – Audible alarm sound level
39 Subclause 201.9.6.2.103 – Audible alarms sound level within COMPARTMENT
Subclause 201.9.8.3.101 – Barriers
Subclause 201.11.2 – Fire prevention
Subclause 201.11.6.2 – Overflow in ME EQUIPMENT
Subclause 201.11.6.6 – Cleaning and disinfection of ME EQUIPMENT and ME SYSTEMS
Subclause 201.12.1.101 – Stability of INCUBATOR TEMPERATURE
40 Subclause 201.12.1.102 – Uniformity of INCUBATOR TEMPERATURE
Subclause 201.12.1.103 – Accuracy of SKIN TEMPERATURE SENSOR
Subclause 201.12.1.104 – Accuracy between SKIN TEMPERATURE and CONTROL TEMPERATURE
Subclause 201.12.1.105 – Accuracy of INCUBATOR TEMPERATURE indication
Subclause 201.12.1.106 – *Accuracy of INCUBATOR TEMPERATURE control
Subclause 201.12.1.107 – Warm-up time
Subclause 201.12.1.108 – Overshoot of INCUBATOR TEMPERATURE
41 Subclause 201.12.1.109 – Accuracy of indication of relative humidity
Subclause 201.12.1.110 – Oxygen control
Subclause 201.12.1.111 – Air velocity
Subclause 201.12.1.112 – Weighing Scale
Subclause 201.12.2.101 – Indication of SKIN TEMPERATURE indication
Subclause 201.12.2.102 – Indication of the mode of operation
42 Subclause 201.12.3.101 – Air circulation fan
Subclause 201.12.3.102 – Connector to SKIN TEMPERATURE SENSOR
Subclause 201.12.4.2.101 – CO2-concentration
Subclause 201.13.2.6 – Leakage of liquid
Subclause 201.15.4.1.101 – Temperature sensors
Subclause 201.15.4.2.1 aa)
Subclause 201.15.4.2.1 dd) and ee)
43 Subclause 201.15.4.2.2.101 – AIR CONTROLLED INCUBATOR range
Subclause 201.15.4.2.2.102 – BABY CONTROLLED INCUBATOR range
Subclause 210.5.1 – Instructions for use
Subclause 210.6.3 – PCLCS VARIABLE logging
Subclause 210.8.2.2.6 – * Responses of the PCLCS
44 Bibliography
45 Index of defined terms used in this particular standard
47 Title page
48 AAMI Standard
Copyright information
49 Contents
50 Glossary of equivalent standards
51 Committee representation
52 Background of ANSI/AAMI adoption of Amendment 1 to IEC 60601-2-19:2009
53 Foreword
55 List of amendments
AAMI 60601 2 19 2009 RA 2014 A1 2016
$115.49