{"id":6661,"date":"2024-10-16T18:42:43","date_gmt":"2024-10-16T18:42:43","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d7057-2009\/"},"modified":"2024-10-24T10:44:25","modified_gmt":"2024-10-24T10:44:25","slug":"astm-d7057-2009","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d7057-2009\/","title":{"rendered":"ASTM-D7057 2009"},"content":{"rendered":"<\/p>\n
1.1 This test method covers the determination of the purity of isopropylbenzene (cumene) by gas chromatography. Calibration of the gas chromatography system is done by the external standard calibration technique.<\/p>\n
1.2 This test method has been found applicable to the measurement of impurities such as nonaromatic hydrocarbons, benzene, toluene, ethylbenzene, phenol, cymenes, t<\/span> -butylbenzene, n<\/span> -butylbenzene, n<\/span> -propylbenzene, alpha<\/span> -methylstyrene, sec<\/span> -butylbenzene, and diisopropylbenzenes, which are impurities that can be found in isopropylbenzene. The latter impurities can be analyzed over a range of 1 mg\/kg to 500 mg\/kg by this method (see Table 1). The limit of detection for these impurities is summarized in Table 1 as well.<\/p>\n 1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E 29 .<\/p>\n 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.<\/p>\n 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.<\/span><\/span><\/p>\n TABLE 1 Summary of Precision Data (mg\/kg)<\/p>\n D7057-09 Standard Test Method for Analysis of Isopropylbenzene (Cumene) by Gas Chromatography (External Standard)<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n Scope
Referenced Documents
Terminology
Summary of Test Method
Significance and Use <\/td>\n<\/tr>\n\n 2<\/td>\n Apparatus
Reagents and Materials
Hazards
TABLE 1
TABLE 2 <\/td>\n<\/tr>\n\n 3<\/td>\n Sampling and Handling
Preparation of Apparatus
Calibration
FIG. 1 <\/td>\n<\/tr>\n\n 4<\/td>\n Procedure
Calculations
Report
Precision and Bias
Quality Guidelines
Keywords <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2009<\/td>\n 5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":6662,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1014,2637],"product_tag":[],"class_list":{"0":"post-6661","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-71-080-15","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/6661","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/6662"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=6661"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=6661"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=6661"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}