{"id":435588,"date":"2024-10-20T07:50:26","date_gmt":"2024-10-20T07:50:26","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-1363-32023-tc\/"},"modified":"2024-10-26T14:51:03","modified_gmt":"2024-10-26T14:51:03","slug":"bs-1363-32023-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-1363-32023-tc\/","title":{"rendered":"BS 1363-3:2023 – TC"},"content":{"rendered":"

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
188<\/td>\nForeword <\/td>\n<\/tr>\n
191<\/td>\n1 Scope
2 Normative references <\/td>\n<\/tr>\n
193<\/td>\n3 Terms and definitions <\/td>\n<\/tr>\n
197<\/td>\n4 Conditions of use
5 General
6 General conditions for type testing <\/td>\n<\/tr>\n
198<\/td>\nTable 1 \u2014 Schedule of tests <\/td>\n<\/tr>\n
199<\/td>\nFigure 5 \u2014 Gauge for plug pins <\/td>\n<\/tr>\n
200<\/td>\nFigure 11 \u2014 GO gauge for socket-outlet <\/td>\n<\/tr>\n
201<\/td>\nFigure 12 \u2014 Contact test gauge <\/td>\n<\/tr>\n
202<\/td>\nFigure 14 \u2014 Non-contact test gauge <\/td>\n<\/tr>\n
203<\/td>\nFigure 16a) \u2014 Withdrawal pull gauges for effectiveness of contact: Gauge for earthing socket contact
7 Classification and rating
7.1 Classifications <\/td>\n<\/tr>\n
204<\/td>\n7.2 Rating
8 Marking and labelling <\/td>\n<\/tr>\n
205<\/td>\nTable 2 \u2014 Rated current and maximum fuse rating in normal use, and load for flexing and cable grip tests related to size of flexible cable <\/td>\n<\/tr>\n
206<\/td>\n9 Clearances, creepage distances and solid insulation <\/td>\n<\/tr>\n
207<\/td>\n9.1 Clearances <\/td>\n<\/tr>\n
208<\/td>\nTable 3 \u2014 Minimum clearances for basic insulation
9.2 Creepage distances <\/td>\n<\/tr>\n
209<\/td>\nTable 4 \u2014 Minimum creepage distances (mm) for basic insulation
9.3 Solid insulation
Table 5 \u2014 Withstand voltages for insulation types <\/td>\n<\/tr>\n
210<\/td>\n9.4 Requirements for printed wiring boards and equivalent construction
10 Accessibility of live parts
Figure 1 \u2014 Test pin <\/td>\n<\/tr>\n
211<\/td>\nFigure 2a) \u2014 Apparatus for mechanical strength test on resilient covers <\/td>\n<\/tr>\n
212<\/td>\nFigure 2b) \u2014 Hardwood block for Figure 2a) <\/td>\n<\/tr>\n
213<\/td>\n11 Provision for earthing <\/td>\n<\/tr>\n
214<\/td>\n12 Terminals and terminations of intermediate adaptors and adaptor plugs <\/td>\n<\/tr>\n
215<\/td>\nTable 6 \u2014 Torque values for screws and nuts <\/td>\n<\/tr>\n
216<\/td>\n13 Construction of adaptors (plug portion)
Figure 4a) \u2014 Dimensions and disposition of pins <\/td>\n<\/tr>\n
219<\/td>\nFigure 4b) \u2014 Concave shrinkage allowance for ISODs <\/td>\n<\/tr>\n
222<\/td>\nFigure 6 \u2014 Apparatus for testing plug cover fixing screws <\/td>\n<\/tr>\n
224<\/td>\nFigure 32a) \u2014 Apparatus for tests on adaptor pins
Figure 32b) \u2014 Apparatus for tests on adaptor plug pins <\/td>\n<\/tr>\n
227<\/td>\nFigure 33 \u2014 Apparatus for torsion test on pins <\/td>\n<\/tr>\n
228<\/td>\nFigure 7 \u2014 Mounting plate <\/td>\n<\/tr>\n
229<\/td>\nFigure 8 \u2014 Plug pin deflection test apparatus for resilient adaptors <\/td>\n<\/tr>\n
231<\/td>\nFigure 9 \u2014 Apparatus for abrasion test on insulating sleeves of plug pins <\/td>\n<\/tr>\n
232<\/td>\nFigure 10 \u2014 Apparatus for pressure test at high temperature <\/td>\n<\/tr>\n
233<\/td>\n14 Construction of adaptors (adaptor socket-outlet portion)
Figure 3 \u2014 Disposition of socket contacts <\/td>\n<\/tr>\n
234<\/td>\nFigure 13 \u2014 Test apparatus and circuit for use with contact and non contact gauges <\/td>\n<\/tr>\n
236<\/td>\nFigure 16b) \u2014 Withdrawal pull gauges for effectiveness of contact: Gauge for line and neutral current carrying socket contacts <\/td>\n<\/tr>\n
238<\/td>\nFigure 35 \u2014 Simulated plug and cable devices <\/td>\n<\/tr>\n
240<\/td>\nFigure 36 \u2014 Apparatus for calibration of turning moment of simulated plug
Figure 37a) \u2014 Turning moment apparatus: Front view and side view <\/td>\n<\/tr>\n
241<\/td>\nFigure 37b) \u2014 Turning moment apparatus: Top view and pictoral overview <\/td>\n<\/tr>\n
243<\/td>\nTable 7 \u2014 Actuator test force
15 Resistance to ageing and to humidity
15.1 Resistance to ageing
15.2 Resistance to humidity <\/td>\n<\/tr>\n
244<\/td>\n16 Insulation resistance and electric strength <\/td>\n<\/tr>\n
245<\/td>\n17 Temperature rise
Figure 34 \u2014 Test plug <\/td>\n<\/tr>\n
247<\/td>\nTable 8 \u2014 Permitted temperature rises <\/td>\n<\/tr>\n
248<\/td>\nFigure 17a) \u2014 Test apparatus for temperature rise test <\/td>\n<\/tr>\n
250<\/td>\nFigure 17b) \u2014 Dummy front plate for temperature rise test <\/td>\n<\/tr>\n
251<\/td>\n18 Breaking capacity of adaptors
19 Normal operation of adaptors <\/td>\n<\/tr>\n
252<\/td>\n20 Connection of flexible cables and cable anchorage in intermediate adaptors and adaptor plugs <\/td>\n<\/tr>\n
255<\/td>\nFigure 18 \u2014 Apparatus for flexing test <\/td>\n<\/tr>\n
256<\/td>\nTable 9 \u2014 Connection of flexible cables
21 Mechanical strength
Figure 19 \u2014 Solid link for test on fuse clips <\/td>\n<\/tr>\n
257<\/td>\nFigure 38 \u2014 Solid links for test on fuse clips <\/td>\n<\/tr>\n
258<\/td>\nFigure 21a) \u2014 Pendulum impact test: General view of apparatus <\/td>\n<\/tr>\n
259<\/td>\nFigure 21b) \u2014 Pendulum impact test: Constructional details of striking elements <\/td>\n<\/tr>\n
260<\/td>\nFigure 21c) \u2014 Pendulum impact test: Constructional details of mounting support for test samples <\/td>\n<\/tr>\n
261<\/td>\nFigure 20 \u2014 Tumbling barrel <\/td>\n<\/tr>\n
262<\/td>\n22 Screws, current carrying parts and connections <\/td>\n<\/tr>\n
263<\/td>\n23 Resistance to heat <\/td>\n<\/tr>\n
264<\/td>\nFigure 23 \u2014 Apparatus for pressure test <\/td>\n<\/tr>\n
265<\/td>\n24 Resistance to abnormal heat and fire
24.1 General
24.2 Glow wire test
Table 10 \u2014 Application of glow wire test <\/td>\n<\/tr>\n
266<\/td>\n25 Resistance to excessive residual stresses and to rusting <\/td>\n<\/tr>\n
267<\/td>\n26 (Not used)
27 Overload tests <\/td>\n<\/tr>\n
269<\/td>\nAnnex A (normative)\u2002 Requirements for incorporated electronic components <\/td>\n<\/tr>\n
274<\/td>\nAnnex B (normative)\u2002 Pollution degree <\/td>\n<\/tr>\n
275<\/td>\nAnnex C (normative)\u2002 Relation between rated impulse withstand voltage, rated voltage and Overvoltage Category
Table C.1 \u2014 Rated impulse withstand voltage for adaptors energized directly from the low voltage mains <\/td>\n<\/tr>\n
276<\/td>\nAnnex D (normative)\u2002 Determination of the Comparative Tracking Index and Proof Tracking Index
Annex E (normative)\u2002 Impulse voltage test <\/td>\n<\/tr>\n
277<\/td>\nTable E.1 \u2014 Test voltages for verifying clearances at sea level
Annex F (normative)\u2002 Measurement of clearances and creepage distances
Table F.1 \u2014 Minimum values of width, X <\/td>\n<\/tr>\n
278<\/td>\nFigure F.1 \u2014 Example 1
Figure F.2 \u2014 Example 2
Figure F.3 \u2014 Example 3 <\/td>\n<\/tr>\n
279<\/td>\nFigure F.4 \u2014 Example 4
Figure F.5 \u2014 Example 5
Figure F.6 \u2014 Example 6 <\/td>\n<\/tr>\n
280<\/td>\nFigure F.7 \u2014 Example 7
Figure F.8 \u2014 Example 8
Figure F.9 \u2014 Example 9 <\/td>\n<\/tr>\n
281<\/td>\nFigure F.10 \u2014 Example 10
Figure F.11 \u2014 Example 11
Annex G (normative)\u2002 Test plug for temperature rise test <\/td>\n<\/tr>\n
282<\/td>\nFigure 30 \u2014 Test plug for temperature rise <\/td>\n<\/tr>\n
283<\/td>\nAnnex H (normative)\u2002 The construction and calibration of a calibrated link <\/td>\n<\/tr>\n
284<\/td>\nFigure 28 \u2014 Calibrated link <\/td>\n<\/tr>\n
286<\/td>\nFigure 29 \u2014 Calibration jig for calibrated link <\/td>\n<\/tr>\n
287<\/td>\nAnnex I (informative)\u2002 Annex identification migration from 2016 edition to 2023 edition <\/td>\n<\/tr>\n
288<\/td>\nTable I.1 \u2014 BS 1363 annex identification migration from 2016 to 2023 <\/td>\n<\/tr>\n
290<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Tracked Changes. 13 A plugs, socket-outlets, adaptors and connection units – Adaptors. Specification<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2023<\/td>\n292<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":435595,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[509,2641],"product_tag":[],"class_list":{"0":"post-435588","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-120-30","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/435588","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/435595"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=435588"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=435588"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=435588"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}