{"id":336578,"date":"2024-10-19T23:31:31","date_gmt":"2024-10-19T23:31:31","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d6390-2005\/"},"modified":"2024-10-25T22:31:54","modified_gmt":"2024-10-25T22:31:54","slug":"astm-d6390-2005","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d6390-2005\/","title":{"rendered":"ASTM-D6390 2005"},"content":{"rendered":"<\/p>\n
1.1 This test method covers the determination of the amount of draindown in an uncompacted asphalt mixture sample when the sample is held at elevated temperatures comparable to those encountered during the production, storage, transport, and placement of the mixture. The test is particularly applicable to mixtures such as porous asphalt (open-graded friction course) and stone matrix asphalt (SMA)<\/p>\n
1.2 The values stated in SI units are to be regarded as the standard.<\/p>\n
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/i><\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Scope Referenced Documents Terminology Summary of Test Method Significance and Use Apparatus <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Sample Preparation Procedure Calculation FIG. 1 <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Report Precision and Bias Keywords TABLE 1 TABLE 2 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" D6390-05 Standard Test Method for Determination of Draindown Characteristics in Uncompacted Asphalt Mixtures<\/b><\/p>\n |