{"id":287446,"date":"2024-10-19T19:29:00","date_gmt":"2024-10-19T19:29:00","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-1366-122014\/"},"modified":"2024-10-25T16:22:46","modified_gmt":"2024-10-25T16:22:46","slug":"bs-en-1366-122014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-1366-122014\/","title":{"rendered":"BS EN 1366-12:2014"},"content":{"rendered":"

This part of EN 1366<\/span> <\/span> specifies a method for determining the fire resistance of non-mechanical fire barriers installed in fire separating elements designed to withstand heat and the passage of smoke and gases at high temperature. This European Standard is used in conjunction with EN 1363\u20111<\/span> <\/span> and EN 1366\u20112<\/span> <\/span>.<\/p>\n

This European Standard is not suitable for testing non-mechanical fire barriers in suspended ceilings without modification.<\/p>\n

This European Standard is not suitable for testing fire dampers, see EN 1366\u20112<\/span> <\/span>.<\/p>\n

This European Standard is not suitable for testing such products as air transfer grilles, as the pressures and flows involved are different and may cause differing behaviour.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
4<\/td>\nContents Page <\/td>\n<\/tr>\n
6<\/td>\nForeword <\/td>\n<\/tr>\n
7<\/td>\nIntroduction <\/td>\n<\/tr>\n
8<\/td>\n1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n
9<\/td>\n4 Test equipment
4.1 General
4.2 Connecting duct
4.3 Volume flow measuring station
4.4 Condensing unit <\/td>\n<\/tr>\n
10<\/td>\n4.5 Gas temperature measuring devices
4.6 Exhaust fan system
5 Test conditions
6 Test specimen
6.1 Size
6.2 Number of tests
6.2.1 General <\/td>\n<\/tr>\n
11<\/td>\n6.2.2 Supporting construction
6.2.3 Method of installation in the supporting construction
6.2.4 Method of installation on to the supporting construction
6.2.5 Method of installation away from the supporting construction <\/td>\n<\/tr>\n
12<\/td>\n6.3 Design
6.3.1 General
6.3.2 Orientation to be tested
6.3.3 Non-mechanical fire barriers installed within a wall or floor opening
6.3.4 Non-mechanical fire barriers mounted on to the face of a wall or floor
6.3.5 Non-mechanical fire barriers mounted remote from a wall or floor
6.3.5.1 General
6.3.5.2 Non-mechanical fire barriers mounted inside the furnace
6.3.5.3 Non-mechanical fire barriers mounted outside the furnace <\/td>\n<\/tr>\n
13<\/td>\n7 Installation of test specimen
7.1 General
7.2 Supporting construction
Table 1 \u2014 Standard floor constructions
7.3 Minimum separation <\/td>\n<\/tr>\n
14<\/td>\n8 Conditioning
8.1 General
8.2 Water-based sealing materials
9 Application of instrumentation
9.1 Thermocouples
9.1.1 Furnace thermocouples (plate thermometers)
9.1.2 Unexposed surface temperature
9.2 Furnace pressure
9.2.1 General
9.2.2 Pressure differential measurement, furnace and connecting duct <\/td>\n<\/tr>\n
15<\/td>\n10 Test procedure
10.1 Determination of leakage of connecting duct and measuring station
10.2 Fire test procedure <\/td>\n<\/tr>\n
16<\/td>\n11 Performance criteria <\/td>\n<\/tr>\n
17<\/td>\n12 Test report <\/td>\n<\/tr>\n
18<\/td>\n13 Field of direct application of test results
13.1 Size of non-mechanical fire barrier
13.2 Non-mechanical fire barriers installed within structural openings
13.3 Non-mechanical fire barriers installed onto the face of a wall or a floor
13.4 Non-mechanical fire barriers remote from a wall or floor <\/td>\n<\/tr>\n
19<\/td>\n13.5 Fire from above
13.6 Separation between non-mechanical fire barriers and between non-mechanical fire barriers and construction elements
13.7 Supporting constructions <\/td>\n<\/tr>\n
21<\/td>\nFigure 1 \u2014 Example of general test arrangement <\/td>\n<\/tr>\n
22<\/td>\nFigure 2 \u2014 Example of an alternative arrangement when testing non-mechanical fire barriers in floor <\/td>\n<\/tr>\n
23<\/td>\nFigure 3 \u2014 Non-mechanical fire barrier mounted in standard supporting construction <\/td>\n<\/tr>\n
24<\/td>\nFigure 4 \u2014 Non-mechanical fire barrier mounted onto face of supporting construction within the furnace <\/td>\n<\/tr>\n
25<\/td>\nFigure 5 \u2014 Non-mechanical fire barrier mounted onto standard supporting construction outside the furnace <\/td>\n<\/tr>\n
26<\/td>\nFigure 6 \u2014 Non-mechanical fire barrier mounted remote from the standard supporting construction and inside the furnace <\/td>\n<\/tr>\n
27<\/td>\nFigure 7 \u2014 Non-mechanical fire barrier mounted remote from the standard supporting construction and outside the furnace <\/td>\n<\/tr>\n
28<\/td>\nFigure 8 \u2014 Non-mechanical fire barrier mounted in an insulated duct <\/td>\n<\/tr>\n
29<\/td>\nFigure 9 \u2014 Detail for the application of thermocouples TS and T1 on the supporting construction at discontinuities <\/td>\n<\/tr>\n
30<\/td>\nFigure 10 \u2014 Minimum separation <\/td>\n<\/tr>\n
31<\/td>\nFigure 11 \u2014 Non-mechanical fire barriers mounted in different horizontal planes <\/td>\n<\/tr>\n
32<\/td>\nAnnex A (normative) EOTA TR026 – Characterization, Aspects of Durability and Factory Production Control for Reactive Materials, Components and Products <\/td>\n<\/tr>\n
33<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Fire resistance tests for service installations – Non-mechanical fire barrier for ventilation ductwork<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2014<\/td>\n36<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":287449,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[240,2641],"product_tag":[],"class_list":{"0":"post-287446","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-13-220-50","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/287446","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/287449"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=287446"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=287446"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=287446"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}